SIMOTION DRIVE-BASED CONTROLLER EXTENSION CX32-2; INVERTER CONTROL MODULE; TO INCREASE DRIVE COUNT ON SIMOTION D4X5-2; INTERFACES: 6 DI, 4 DI/DO, 4 DRIVE-CLIQ

Артикул: 6AU1432-2AA00-0AA0
Производитель: Siemens


Наименование продукта
SIMOTION DRIVE-BASED CONTROLLER EXTENSION CX32-2; INVERTER CONTROL MODULE; TO INCREASE DRIVE COUNT ON SIMOTION D4X5-2; INTERFACES: 6 DI, 4 DI/DO, 4 DRIVE-CLIQ
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2011-05-11
Controller Extension SIMOTION CX32-2, Abb. ähnlich
SIMOTION DRIVE-BASED CONTROLLER EXTENSION CX32-2; INVERTER CONTROL MODULE; TO INCREASE DRIVE COUNT ON SIMOTION D4X5-2; INTERFACES: 6 DI, 4 DI/DO, 4 DRIVE-CLIQ
Integrierte Antriebsregelung
 
Number of axes  
  • for servo control / maximum
6
  • for U/f control / maximum
12
  • for vector control / maximum
6
  • for U/f control / maximum / remark
(alternative) Drive control based on SINAMICS S120 CU320-2, firmware version V4.x
Kommunikation
 
Number of interfaces  
  • as DRIVE-CLiQ interface
4
Buffer time / of the retentive memory / minimum / remark unlimited
Allgemeine technische Daten
 
Fan version No fan
Supply voltage / for DC / rated value 24 V
Supply voltage 20.4 28.8 V
own current drawn / typical 300 mA
  • remark
without load at the inputs/outputs, without 24 V supply via DRIVE-CLiQ interface
Inrush current / typical 1.6 A
Active power loss / typical 7 W
Ambient temperature  
  • during transport
-40 +70 °C
  • during operating
0 °C 55 °C
Relative humidity / without condensation  
  • during operating phase
5 90 %
Air pressure 620 1060 hPa
Protection class IP IP20
Height 380 mm
Width 25 mm
Depth 270 mm
  • remark
(when the spacer is removed 230 mm deep)
Net weight 2600 g
Number of digital inputs 6
Input voltage / at the digital input  
  • for DC / rated value
24 V
  • initial value for signal<1>-recognition
15 V
  • final value for signal<1>-recognition
30 V
  • initial value for signal<0>-recognition
-3 V
  • final value for signal<1>-recognition
5 V
Electrical isolation / at the digital input Yes
  • between the channels and the electronics power supply / remark
(Yes, in groups of 4)
Current drawn / at the digital input/output for digital input signals / for signal <1> 9 mA
Input delay time / at the digital input  
  • for signal <0> to <1> / typical
50 µs
  • for signal <1> to <0> / typical
150 µs
Number of digital inputs/outputs 4
Design of the electrical connection / of the inputs and outputs parameterizable - as DI - as DO - as probe input (max. 4)
Bei Verwendung als Eingang
 
Input voltage / at the digital input/output for digital input signals  
  • for DC / rated value
24 V
  • initial value for <1> signal detection
15 V
  • final value for <1> signal detection
30 V
  • initial value for <0> signal detection
-3 V
  • final value for <0> signal detection
5 V
Electrical isolation / at the digital input/output for the digital inputs signals / between the channels and electronics power supply No
Current drawn / at the digital input / for signal <1> / typical 9 mA
Input delay time  
  • at the digital input/output for digital input signals / for signal <0> to <1> / typical
5 µs
Reproducibility of the edge detection / at the digital input/output for digital input signals as probe input 5 µs
Bei Verwendung als Ausgang
 
Output voltage / at the digital input/output for digital output signals / for signal <1> / for DC / rated value 24 V
Output voltage / at the digital input/output for digital output signals  
  • for signal <1>
20.4 28.8 V
Electrical isolation / at the digital input/output for digital output signals / between the channels and electronics power supply No
Current load capability / at the digital input/output for digital output signals / maximum 500 mA
Leakage current / at the digital input /output for digital output signals / maximum 2 mA
Delay time for the signal change / at the digital input/output for digital output signals / for ohmic load  
  • for signal <0> to <1>
150 400 µs
  • for signal <1> to <0>
75 100 µs
Switching frequency / at the digital input/output for digital output signals  
  • for ohmic load / maximum
100 Hz
  • for inductive load / maximum
2 Hz
  • for incandescent lamp load / maximum
11 Hz
Product function / at the digital input/output for digital output signals / short-circuit protection Yes
Weitere technische Daten
 
Verification of suitability  
  • as authorisation for USA
Назад в раздел