SIMOTION DRIVE-BASED CONTROL UNIT D445-1; PROGRAMMABLE MOTION CONTROLLER; HIGH PERFORMANCE; INTERFACES: 8 DI, 8 DI/DO, 6 DRIVE-CLIQ, 2 PROFIBUS, 2 ETHERNET, 2 USB, 1 OPTION SLOT; INCL. DUAL FAN / BATTERY MODULE AND BATTERY (REQUIRES>=V4.1 SP2 HF3/4)

Артикул: 6AU1445-0AA00-0AA1
Производитель: Siemens


Наименование продукта
SIMOTION DRIVE-BASED CONTROL UNIT D445-1; PROGRAMMABLE MOTION CONTROLLER; HIGH PERFORMANCE; INTERFACES: 8 DI, 8 DI/DO, 6 DRIVE-CLIQ, 2 PROFIBUS, 2 ETHERNET, 2 USB, 1 OPTION SLOT; INCL. DUAL FAN / BATTERY MODULE AND BATTERY (REQUIRES>=V4.1 SP2 HF3/4)
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2009-02-17
SIMOTION D445/D445-1, offen, ohne CompactFlash, Abb. ähnlich
SIMOTION DRIVE-BASED CONTROL UNIT D445-1; PROGRAMMABLE MOTION CONTROLLER; HIGH PERFORMANCE; INTERFACES: 8 DI, 8 DI/DO, 6 DRIVE-CLIQ, 2 PROFIBUS, 2 ETHERNET, 2 USB, 1 OPTION SLOT; INCL. DUAL FAN / BATTERY MODULE AND BATTERY (REQUIRES >=V4.1 SP2 HF3/4)
PLC- und Motion Control Performance
 
Number of axes / maximum 64
Bus clock cycle / acc. to PROFIBUS / remark 1 ms
Send clock cycle / acc. to PROFINET / minimum 0.5 ms
Interpolator clock cycle / minimum 0.5 ms
Servo clock cycle / minimum 0.5 ms
Integrierte Antriebsregelung
 
Number of axes  
  • for servo control / maximum
6
  • for U/f control / maximum
8
  • for vector control / maximum
4
  • for U/f control / maximum / remark
(alternative) Drive control based on SINAMICS S120 CU320, firmware version V2.x
Speicher
 
Memory capacity  
  • of the RAM work memory
96 Mbyte
  • on RAM / for Java applications
20 Mbyte
  • of the RAM load memory
47 Mbyte
  • of the retentive memory
364 kbyte
  • of the user memory / as persistent memory
300 Mbyte
Kommunikation
 
Number of interfaces  
  • as DRIVE-CLiQ interface
6
  • according to USB
2
  • according to Industrial Ethernet
2
  • acc. to PROFIBUS
2
  • remark
- Equidistant and isochronous - Can be configured as master or slave
  • according to PROFINET
0
Optionally over CBE30: - 1 interface with 4 ports - supports PROFINET IO with IRT and RT - can be configured as PROFINET IO controller and/or device
Allgemeine technische Daten
 
Fan version Double fan/battery module included in scope of delivery
Supply voltage / for DC / rated value 24 V
Supply voltage 20.4 28.8 V
own current drawn / typical 1000 mA
  • remark
without load at the inputs/outputs, without 24 V supply via DRIVE-CLiQ and PROFIBUS interface
Inrush current / typical 5 A
Active power loss / typical 24 W
Ambient temperature  
  • during storage
-40 +70 °C
  • during transport
-40 +70 °C
  • during operating
0 °C 55 °C Maximum 5000 m (16405 ft) above sea level. Above an altitude of 2000 m (6562 ft), the max. ambient temperature decreases by 7 °C (44.6 °F) every 1000 m (3281 ft).
Relative humidity / without condensation  
  • during operating phase
5 95 %
Air pressure 700 1060 hPa
Protection class IP IP20
Height 380 mm
Width 50 mm
Depth 270 mm
  • remark
(when the spacer is removed 230 mm deep)
Net weight 3100 g
Number of digital inputs 8
Input voltage / at the digital input  
  • for DC / rated value
24 V
  • initial value for signal<1>-recognition
15 V
  • final value for signal<1>-recognition
30 V
  • initial value for signal<0>-recognition
-3 V
  • final value for signal<1>-recognition
5 V
Electrical isolation / at the digital input Yes
  • between the channels and the electronics power supply / remark
(Yes, in groups of 6)
Current drawn / at the digital input/output for digital input signals / for signal <1> 10 mA
Input delay time / at the digital input  
  • for signal <0> to <1> / typical
50 µs
  • for signal <1> to <0> / typical
150 µs
Number of digital inputs/outputs 8
Design of the electrical connection / of the inputs and outputs parameterizable - as DI - as DO - as probe input (max. 6) - as cam output (max. 8 )
Bei Verwendung als Eingang
 
Input voltage / at the digital input/output for digital input signals  
  • for DC / rated value
24 V
  • initial value for <1> signal detection
15 V
  • final value for <1> signal detection
30 V
  • initial value for <0> signal detection
-3 V
  • final value for <0> signal detection
5 V
Electrical isolation / at the digital input/output for the digital inputs signals / between the channels and electronics power supply No
Current drawn / at the digital input / for signal <1> / typical 10 mA
Input delay time  
  • at the digital input/output for digital input signals / for signal <0> to <1> / typical
5 µs
Reproducibility of the edge detection / at the digital input/output for digital input signals as probe input 5 µs

Назад в раздел