SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 2 AI RTD 15 MM WIDE, 15BIT + SIGN PT100 STD; PT100 KL; NI100 STD; NI100 KL; 150 OHM; 300 OHM; 600 OHM, CYCLE TIME 110 MS/CHANNEL WITH LED SF (GROUP FAULT)

Артикул: 6ES7134-4JB50-0AB0
Производитель: Siemens


Наименование продукта
SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 2 AI RTD 15 MM WIDE, 15BIT + SIGN PT100 STD; PT100 KL; NI100 STD; NI100 KL; 150 OHM; 300 OHM; 600 OHM, CYCLE TIME 110 MS/CHANNEL WITH LED SF (GROUP FAULT)
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
1998-10-30 2008-09-16 2008-09-16
Manuals weitere>>
ET 200S Distributed I/O System  2004-09-14
SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 2 AI RTD 15 MM WIDE, 15BIT + SIGN PT100 STD; PT100 KL; NI100 STD; NI100 KL; 150 OHM; 300 OHM; 600 OHM, CYCLE TIME 110 MS/CHANNEL WITH LED SF (GROUP FAULT)
Supply voltage
Load voltage L+
Rated value (DC) 24 V; From power module
Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 30 mA
from backplane bus 3.3 V DC, max. 10 mA
Output voltage
Power supply to the transmitters
present Yes
short-circuit proof Yes
Power losses
Power loss, typ. 0.6 W
Address area
Address space per module
Address space per module, max. 4 byte
Analog inputs
Number of analog inputs 2
permissible input voltage for voltage input (destruction limit), max. 9 V
Constant measurement current for resistance-type transmitter, typ. 1.5 mA
Cycle time (all channels) max. Number of active channels per module x basic conversion time
Input ranges
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), resistance thermometers
Ni 100 Yes; Standard/climate
Input resistance (Ni 100) 2000 kΩ
Pt 100 Yes; Standard/climate
Input resistance (Pt 100) 2000 kΩ
Input ranges (rated values), resistors
0 to 150 ohms Yes
Input resistance (0 to 150 ohms) 2000 kΩ
0 to 300 ohms Yes
Input resistance (0 to 300 ohms) 2000 kΩ
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 2000 kΩ
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer Pt100, Ni100
Characteristic linearization
Parameterizable Yes; for Pt100, Ni100
Cable length
Cable length, shielded, max. 200 m
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 16 bit; 150 ohms: 14 bits; 300, 600 ohms: 15 bits, Pt100, Ni100: 16 bits
Integration time, parameterizable Yes
Integration time, ms 16.7 / 20 ms
Interference voltage suppression for interference frequency f1 in Hz 60 / 50 Hz
Conversion time (per channel) 110 ms; 110 / 130 ms
Smoothing of measured values
Parameterizable Yes; In four stages by means of digital filtering
Step: None Yes; 1 x cycle time
Step: low Yes; 4 x cycle time
Step: Medium Yes; 64 x cycle time
Step: High Yes; 128 x cycle time
Encoder
Connection of signal encoders
for resistance measurement with 2-conductor connection Yes; Line resistances are included in the measurement, jumpers on TR
for resistance measurement with 3-conductor connection Yes; Line resistances are included in the measurement, jumpers on TR
for resistance measurement with 4-conductor connection Yes
Burden of 2-wire transmitter, max. 750 Ω
Errors/accuracies
Linearity error (relative to input area) +/- 0,01 %
Temperature error (relative to input area) +/- 0,005 %/K
Crosstalk between the inputs, min. -50 dB
Repeat accuracy in settled status at 25 °C (relative to input area) +/- 0,05 %
Operational limit in overall temperature range
Resistance-type thermometer, relative to input area +/- 0,6 %
Basic error limit (operational limit at 25 °C)
Resistance-type thermometer, relative to input area +/- 0,4 %
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency
Series mode interference (peak value of interference < rated value of input range), min. 70 dB
common mode voltage (USS < 2.5 V) , min. 90 dB
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Diagnostic messages
Diagnostic functions Yes; Can be read out
Wire break Yes; Wire break is detected only on constant current lines
Group error Yes
Overflow/underflow Yes
Diagnostics indication LED
Group error SF (red) Yes
Parameter
Diagnosis: wire break Disable/enable (wire break is detected only on constant current lines)
Measurement type/range deactivated/150 ohms/; 300 ohms/600 ohms/; Pt100 climatic/ Pt100 standard; Ni100 standard / Ni100 climatic
Group diagnostics Disable / enable
Overflow/underflow Disable / enable
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
between the channels and the load voltage L+ Yes
Permissible potential difference
between MANA and M internally (UISO) 75 VDC / 60 VAC
Isolation
Isolation checked with 500 V DC
Dimensions
Width 15 mm
Height 81 mm
Depth 52 mm
Weight
Weight, approx. 40 g
Status Mar 12, 2012
Оборудование снято с производства, прямой заменой является:
Part number:6ES7134-4JB51-0AB0
Notes: