| SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 4SI SIRIUS, 4 POINT-TO-POINT INTERFACES 15MM WIDTH, IO-LINK MASTER FOR SIRIUS SWITCHGEAR |
|
General technical data: |
product brand name | | SIRIUS |
product designation | | ET200S interface module for SIRIUS controls with IO-Link |
Protection class IP | | IP20 |
Degree of pollution | | 2 according to IEC 61131 |
Insulation voltage / rated value | V | 500 |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Ambient temperature | | |
| °C | -40… +70 |
- with vertical mounting position
| | |
| °C | 0… 50 |
- with horizontal mounting position
| | |
| °C | 0… 60 |
| °C | -40… +70 |
Relative humidity | | |
| % | 15… 95 |
Conductor-bound parasitic coupling BURST | | |
- according to IEC 61000-4-4
| | 2 kV |
Conductor-bound parasitic coupling conductor-earth SURGE | | |
- according to IEC 61000-4-5
| | 2 kV |
Conductor-bound parasitic coupling conductor-conductor SURGE | | |
- according to IEC 61000-4-5
| | 1 kV |
Electrostatic discharge / according to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m |
Resistance against shock | | 15g / 11 ms |
Resistance against vibration | | 0.35 mm / 5g |
|
Communication: |
Protocol / will be supported / IO-Link protocol | | Yes |
IO-Link transfer rate | | COM2 (38,4 kBaud) |
Operation mode at input/ output link | | IO-Link, deactivated |
Design of the electrical connection | | Connection using terminal module |
Data volume | | |
- of the address range of the inputs / with cyclical transfer
| | |
- per IO-Link port / maximum
| byte | 8 |
| byte | 32 |
- of the address range of the outputs / with cyclical transfer
| | |
- per IO-Link port / maximum
| byte | 8 |
- for all IO-Link ports / maximum
| byte | 32 |
Number of IO-Link ports | | 4 |
Design of cable | | unshielded |
Point-to-point cycle time | | |
- between master and IO-Link device / minimum
| ms | 5 |
- between the master and the backplane bus / minimum
| ms | 5 |
Type of IO-Link device / connectable | | SIRIUS switching technology |
Product function | | |
| | Yes |
| | No |
| | Yes |
Galvanic isolation | | |
| | No |
- between the ports and the backplane bus
| | Yes |
Type of voltage | | |
| | DC |
Supply voltage / 1 / for DC | | |
| V | 24 |
Consumed current / for rated value of the supply voltage | | |
| A | 0.3 |
Active power loss / total / typical | W | 1 |
|
Short-circuit: |
Short-circuit firmness | | 0.4 A per port |
|
Installation/mounting/dimensions: |
Built in orientation | | any |
Type of mounting | | clip-on |
Width | mm | 15 |
|
Certificates/approvals: |
Verification of suitability | | CE / UL / CSA |
Verification of suitability / for gas explosion protection for zone 1/2 | | zone 2 |
General Product Approval | other | ROSTEST | Manufacturer | | | | | |
|
Further information: |
Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/industrial-controls/catalogs |
Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall |
CAx-Online-Generator http://www.siemens.com/cax |
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3RK1005-0LB00-0AA0/all |
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RK1005-0LB00-0AA0 |
|
|
| |
|
last change: | Feb 6, 2012 |