| AS INTERFACE SAFETY AT WORK SLIMLINE S22,5F CAGE CLAMP TERMINAL IP20 2F-DI |
|
General technical data: |
Design of the product | | Safe SlimLine module S22,5F, 2F-DI |
Type | | 2 inputs, safe |
I/O configuration | | 0 |
Protocol / will be supported / AS interface protocol | | Yes |
Design of the electrical connection / of the inputs and outputs | | spring-loaded terminals |
operating voltage | | |
- according to AS-Interface spezification
| V | 26.5… 31.5 |
AS interface / total current input / max | mA | 45 |
Addressing | | front addressing socket |
Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | A |
- according to DIN EN 61346-2
| | A |
|
Inputs: |
Number of digital inputs / safety-related | | 2 |
Inputs | | |
| | mechanical switching contact |
| | contact closed |
| | contact open |
Input current / at the digital input / for signal <1> / minimum | mA | 5 |
|
Outputs: |
Type of voltage / of the outputs | | DC |
|
|
Status display |
| | yellow LED |
- display of AS-Interface/diagnostics
| | green/red LED |
|
Ambient conditions: |
Ambient temperature | | |
| °C | -25… 70 |
| °C | -40… 85 |
Protection class IP | | IP20 |
|
Mechanical design: |
Width | mm | 22.5 |
Height | mm | 90 |
Depth | mm | 91 |
Type of mounting | | standard rail mounting/wall mounting |
|
Certificates/approvals: |
AS-Interface certificate | | yes |
Approvals | | UL, CSA |
General Product Approval | Functional Safety / Safety of Machinery | | |
| |
|
last change: | Oct 31, 2011 |