SIPLUS ET200S EM 2AI STANDARD I -25 ... +60 DEGREES C BASED ON 6ES7134-4GB01-0AB0

Артикул: 6AG1134-4GB01-2AB0
Производитель: Siemens


Наименование продукта
SIPLUS ET200S EM 2AI STANDARD I -25 ... +60 DEGREES C BASED ON 6ES7134-4GB01-0AB0
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2007-09-06
SIPLUS ET200S EM 2AI STANDARD I -25 ... +60 DEGREES C BASED ON 6ES7134-4GB01-0AB0
Supply voltage
Load voltage L+
Rated value (DC) 24 V; From power module
Reverse polarity protection Yes; Destruction limit 35 mA per channel
Input current
from load voltage L+ (without load), max. 80 mA
from backplane bus 3.3 V DC, max. 10 mA
Power losses
Power loss, typ. 0.6 W
Address area
Address space per module
Address space per module, max. 4 byte
Analog inputs
Number of analog inputs 2
Cycle time (all channels) max. Number of active channels per module x basic conversion time
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
Voltage No
Current Yes
Thermocouple No
Resistance thermometer No
Resistance No
Input ranges (rated values), currents
4 to 20 mA Yes; on 50 ohms
Cable length
Cable length, shielded, max. 200 m
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 13 bit; 4 to 20 mA: 13 bits
Integration time, ms 16.7 / 20 ms
Interference voltage suppression for interference frequency f1 in Hz 60 / 50 Hz
Conversion time (per channel) 65 ms; 55 / 65 ms
Smoothing of measured values
Parameterizable Yes; In four stages by means of digital filtering
Step: None Yes; 1 x cycle time
Step: low Yes; 4 x cycle time
Step: Medium Yes; 32 x cycle time
Step: High Yes; 64 x cycle time
Encoder
Connection of signal encoders
Burden of 2-wire transmitter, max. 750 Ω
Errors/accuracies
Linearity error (relative to input area) +/- 0,01 %
Temperature error (relative to input area) +/- 0,005 %/K
Crosstalk between the inputs, min. -50 dB
Repeat accuracy in settled status at 25 °C (relative to input area) +/- 0,05 %
Operational limit in overall temperature range
Current, relative to input area +/- 0,6 %
Basic error limit (operational limit at 25 °C)
Current, relative to input area +/- 0,4 %
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency
Series mode interference (peak value of interference < rated value of input range), min. 70 dB
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Diagnostic messages
Wire break Yes
Group error Yes
Overflow/underflow Yes
Diagnostics indication LED
Group error SF (red) Yes
Parameter
Measurement type/range deactivated / 4 to 20 mA
Group diagnostics Disable / enable
Overflow/underflow Disable / enable
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
between the channels and the load voltage L+ No
Isolation
Isolation checked with 500 V DC
Standards, approvals, certificates
CE mark Yes
UL approval Yes
Ambient conditions
Extended ambient conditions
Relative to ambient temperature-atmospheric pressure-installation altitude Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)
Relative humidity
with condensation / maximum 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
Resistance
to biologically active substances / conformity with EN 60721-3-3 Yes; , Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
to chemically active substances / conformity with EN 60721-3-3 Yes; , Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
to mechanically active substances / conformity with EN 60721-3-3 Yes; , Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Mechanical and climatic conditions during operation
Climatic conditions in operation
Temperature
Min. -25 °C; = Tmin
max. 60 °C; = Tmax
Dimensions
Width 15 mm
Height 81 mm
Depth 52 mm
Weight
Weight, approx. 40 g
Status Apr 9, 2012