SIPLUS ET200S EM 2AI TC HF 0 ... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7134-4NB01-0AB0 . 15 MM WIDE, 15 BIT + SIGN WITH INTERNAL TEMERATURE COMPENSATION

Артикул: 6AG1134-4NB01-7AB0
Производитель: Siemens


Наименование продукта
SIPLUS ET200S EM 2AI TC HF 0 ... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7134-4NB01-0AB0 . 15 MM WIDE, 15 BIT + SIGN WITH INTERNAL TEMERATURE COMPENSATION
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2011-01-15
SIPLUS ET200S EM 2AI TC HF 0 ... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7134-4NB01-0AB0 . 15 MM WIDE, 15 BIT + SIGN WITH INTERNAL TEMERATURE COMPENSATION
Supply voltage
Load voltage L+
Rated value (DC) 24 V; From power module
Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 30 mA
from backplane bus 3.3 V DC, max. 10 mA
Power losses
Power loss, typ. 0.6 W
Address area
Address space per module
Address space per module, max. 4 byte
Analog inputs
Number of analog inputs 2
permissible input voltage for voltage input (destruction limit), max. 20 V; +/-20 V, continuous
Cycle time (all channels) max. Number of active channels per module x basic conversion time
Technical unit for temperature measurement adjustable Yes
Input ranges
Voltage Yes
Current No
Thermocouple Yes
Resistance thermometer No
Resistance No
Input ranges (rated values), voltages
-80 mV to +80 mV Yes
Input resistance (-80 mV to +80 mV) 1 MΩ
Input ranges (rated values), thermoelements
Type B Yes
Input resistance (Type B) 1 MΩ
Type C Yes
Input resistance (Type C) 1 MΩ
Type E Yes
Input resistance (Type E) 1 MΩ
Type J Yes
Input resistance (type J) 1 MΩ
Type K Yes
Input resistance (Type K) 1 MΩ
Type L Yes
Input resistance (Type L) 1 MΩ
Type N Yes
Input resistance (Type N) 1 MΩ
Type R Yes
Input resistance (Type R) 1 MΩ
Type S Yes
Input resistance (Type S) 1 MΩ
Type T Yes
Input resistance (Type T) 1 MΩ
Thermocouple (TC)
for thermocouples Type B, C, E, J, K, L, N, R, S, T to IEC 584
Temperature compensation
internal temperature compensation Yes; possible with TM-E15S24-AT, TM-E15C24-AT
external temperature compensation with compensations socket Yes; one external compensating box per channel
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 50 m
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 16 bit
Integration time, ms 16.7 / 20 ms
Interference voltage suppression for interference frequency f1 in Hz 60 / 50 Hz
Conversion time (per channel) 66 ms; 66 / 80 ms; additional conversion time for diagnostic wire break test
Smoothing of measured values
Parameterizable Yes; In four stages by means of digital filtering
Step: None Yes; 1 x cycle time
Step: low Yes; 4 x cycle time
Step: Medium Yes; 32 x cycle time
Step: High Yes; 64 x cycle time
Errors/accuracies
Linearity error (relative to input area) +/- 0,01 %
Temperature error (relative to input area) +/- 0,005 %/K
Crosstalk between the inputs, min. -50 dB
Repeat accuracy in settled status at 25 °C (relative to input area) +/- 0,05 %
Operational limit in overall temperature range
Voltage, relative to input area +/- 0,1 %; +/-1.5 K for thermocouples, +/-7 K for thermocouples type C,+/-2.5 K with static thermal state (ambient temperature change < 0.3 K/min)
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area +/- 0,05 %; +/-1 K with thermocouples, +/-5 K with thermocouples type C, +/-1.5 K with static thermal state (ambient temperature change < 0.3 K/min)
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency
Series mode interference (peak value of interference < rated value of input range), min. 70 dB
common mode voltage (USS < 2.5 V) , min. 90 dB
Interrupts/diagnostics/status information
Diagnostic messages
Wire break Yes; only thermocouples
Group error Yes
Overflow/underflow Yes
Diagnostics indication LED
Group error SF (red) Yes
Parameter
Diagnosis: wire break Disable / enable (wire break is detected only in thermocouples)
Measurement type/range Deactivated/ +/- 80 mV/ TC-EL Type T (Cu-CuNi)/ TC-EL Type K (NiCr-Ni)/ TC-EL Type B (PtRh-PtRh)/ TC-EL Type c (Wer-Wer) TC-EL Type N (NiCrSi-NiSi)/ TC-EL Type E (NiCr-CuNi)/ TC-EL Type R (PtRh-Pt)/ TC-EL Type S (PtRh-Pt)/ TC-EL Type J (Fe-Cu-Ni)/ TC
Group diagnostics Disable / enable
Overflow/underflow Disable / enable
Comparison point none / yes, internal
Unit Celsius / Fahrenheit
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
between the channels and the load voltage L+ Yes
Permissible potential difference
between inputs and MANA (UCM) 140 V DC/100 V AC
between MANA and M internally (UISO) 75 VDC / 60 VAC
Isolation
Isolation checked with 500 V DC
Standards, approvals, certificates
CE mark Yes
Ambient conditions
Extended ambient conditions
Relative to ambient temperature-atmospheric