| SUBRACK FOR HEATING SYSTEM CONTROL SIPLUS HCS716I - VERSION MOUNTING FRAME - WITHOUT FLANGE. FOR INTEGRATION OF MAX. 12 POWER MODULES LA716, LA716I AND LA716I HP. EACH L-MODULE IS CONNECTED VIA DIRECT CONNECTOR ON A BUS BOARD, WHICH IS MOUNTED ON THE REAR OF THE SUBRACK. THE CONTROL MODULE WITH THE DPC31 ASIC FOR PROFIBUS CONNECTION IS MOUNTED ON RIGHT SIDE OF THE HOUSING |
Product brand name | | SIPLUS |
|
Inputs/ Outputs: | | |
Number of slots | | 12 |
|
General technical data: | | |
Type of power output / connectable | | LA716 / LA716I / LA716I HP |
Number of status displays | | 4 |
|
Communication: | | |
Design of the interface | | PROFIBUS DP |
|
Supply voltage: | | |
Type of voltage / of supply voltage | | AC |
Supply voltage / for AC / rated value | V | 230 |
Relative negative tolerance / of supply voltage | % | 18 |
Relative positive tolerance / of supply voltage | % | 15 |
Supply voltage frequency | | |
| Hz | 50… 60 |
Relative symmetrical tolerance / of the supply voltage frequency | % | 5 |
Stored energy time / at mains power cut | ms | 20 |
Recovery time / after mains power cut / typical | s | 1 |
Power capacity | | |
- with fan / per rack / maximum
| kW | 124 |
- without fan / per rack / maximum
| kW | 67 |
|
Ambient conditions: | | |
Protection class IP | | IP00 |
Resistance against shock / according to IEC 60068-2-27 | | 15g / 11 ms / 3 shocks / axis |
Resistance against vibration / according to IEC 60068-2-6 | | 10 ... 58 Hz: 0.075 mm, 58 ... 500 Hz: 1g |
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV voltage supply cables / 2 kV signal cables |
Conductor-bound parasitic coupling SURGE / according to IEC 61000-4-5 | | on supply cables: 1 kV symmetrical, 2 kV asymmetrical |
Conducted interference as high-frequency radiation / according to IEC 61000-4-6 | | 10 V in the frequency range 0.15 to 80.0 MHz, Mmdulation 80% AM at 1 kHz, evaluation criterion A |
Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV (mains), 1 kV (Profibus) |
Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
Electrostatic discharge / according to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m (80 MHz ... 1000 MHz) |
EMC emitted interference | | Limit value class A to EN 55011 group 1 |
Installation altitude / at a height over sea level / maximum | m | 1,500 |
Ambient temperature | | |
| °C | -40… 70 |
| °C | 0… 55 |
| °C | -40… 70 |
Air pressure | | |
| hPa | 860… 1,080 |
| hPa | 660… 1,080 |
|
Connections: | | |
|
terminals | | |
Nature of the ventilation | | Self ventilation or forced ventilation |
Design of the electrical connection | | plug, 2-pole |
Type of the connectable conductor cross-section | | |
| | 1x (0.2 ... 2.5 mm2) |
- finely stranded / with wire end processing
| | 1x (0.25 ... 2.5 mm2) |
| | 24 ... 12 |
|
Installation/mounting/dimensions: | | |
Built in orientation | | horizontal |
Width | mm | 510 |
Height | mm | 310 |
Depth | mm | 330 |
|
Certificates/approvals: | | |
Verification of suitability | | CE |
|
|
Further information: |
Information- and Downloadcenter (Catalogs, Brochures,…) http://www.automation.siemens.com/mcms/topics/en/siplus/industrial-heating-control/Pages/home.aspx |
Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall |
Cax online generator: http://www.siemens.com/cax |
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/6BK1700-2AA70-0AA0/all |
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=6BK1700-2AA70-0AA0 |
|
|
| |
|
last change: | Oct 17, 2011 |