Low-Voltage Power Distribution and Electrical Installation Technology (Низковольтная техника энергораспределения и электромонтажа)

Артикул Наименование Производитель
3VL6160-1KN30-.... CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. NMX3B600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 600A, RATED CURRENT II= 3000...6000A SHORT-CIRCUIT PROTECTION IR= 600A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL6160-1JM30-.... CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. NMX3E600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 600A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL6160-1JH30-.... CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. NMX3D600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 600A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL6160-1GH30-.... CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. NMX3U600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 600A, RATED CURRENT ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL6160-1GE30-.... CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. NMX3P600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSI TU= 40 DEGR. CELSIUS IN= 600A, RATED CURRENT ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL6160-1GD30-.... CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. NMX3X600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 600A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL6160-1GB30-.... CIRCUIT-BREAKER VL 800 UL; TYPE MG (CAT NO. NMX3N600) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LI TU= 40 DEGR. CELSIUS IN= 600A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 200-600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL5763-3UM36-0A.. CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5763-3UL36-0A.. CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/3WIRES IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5763-3MH36-0A.. CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5763-3LF46-.... CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-3LE36-.... CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-3LB36-.... CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-3LA46-.... CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-2UM36-0A.. CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5763-2MH36-0A.. CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5763-2LF46-.... CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-2LE36-.... CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-2LB36-.... CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-2LA46-.... CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-1UM36-0A.. CIRCUIT-BREAKER VL 630N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5763-1MH36-0A.. CIRCUIT-BREAKER VL 630N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=630A, RATED CURRENT IR=252-630A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5763-1LF46-.... CIRCUIT-BREAKER VL 630N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-1LE36-.... CIRCUIT-BREAKER VL 630N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, ISD=1.5 TO 9 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-1LB36-.... CIRCUIT-BREAKER VL 630N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5763-1LA46-.... CIRCUIT-BREAKER VL 630N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 630A, RATED CURRENT IR= 252...630A, OVERLOAD PROTECTION, II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5750-3MS36-0A.. CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY R.U.S.-C.BR.C.= 100 KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IN=500A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 12.5 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5750-3LS36-.... CIRCUIT-BREAKER VL 630L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IR=200...500A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 12,5 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL5750-2MS36-0A.. CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IN=500A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 12.5 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL5750-2LS36-.... CIRCUIT-BREAKER VL 630H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IR=200...500A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 12,5 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens

Товары 301 - 330 из 5502