A5E0

Артикул Наименование Производитель
A5E02559144 LC500,7ML55170AXX12AA1, DN2513 FORM R13 SITRANS LC 500, SINGLE PIECE FLANGED WITH ROD SENSOR INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL AND INTERFACE TRANSMITTER FOR EXTREME AND CRITICAL PROCESS CONDITIONS, SUCH AS OIL AND LIQUID GAS,TOXIC AND AGGRESSIVE CHEMICALS AND VAPOURS. SIEMENS
A5E02556801 XPS-15,7ML11183XA30,X=125M ECHOMAX XPS-15 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 15 M SIEMENS
A5E02554471 LC500,7ML55152AXX11AA1-2" SAN-Y-01-3000 SITRANS LC500,THREADED OR WELDED FLANGE, WITH ROD SENSOR INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL AND INTERFACE TRANSMITTER FOR EXTREME AND CRITICAL PROCESS CONDITIONS, SUCH AS OIL AND LIQUID GAS, TOXIC AND AGGRESSIVE CHEMICALS AND VAPOURS. SIEMENS
A5E02551263 5 FT ENCODER INTERFACE CABLE WITH IP68 NEMA 6P PLUGS INCLUDED FOR ITRON 200WP RADIO SIEMENS
A5E02551182 25 FT ENCODER INTERFACE CABLE WITH IP68 NEMA 6P PLUGS INCLUDED FOR ITRON 200WP RADIO SIEMENS
A5E02545442 LC500,7ML5515-0AXX4-2AA1-Z, TYPE F FLANGE. SITRANS LC500,THREADED OR WELDED FLANGE, WITH ROD SENSOR INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL AND INTERFACE TRANSMITTER FOR EXTREME AND CRITICAL PROCESS CONDITIONS, SUCH AS OIL AND LIQUID GAS, TOXIC AND AGGRESSIVE CHEMICALS AND VAPOURS. SIEMENS
A5E02545441 LC500,7ML5515-0AL54-2AA1-Z, TYPE F FLANGE. SITRANS LC500,THREADED OR WELDED FLANGE, WITH ROD SENSOR INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL AND INTERFACE TRANSMITTER FOR EXTREME AND CRITICAL PROCESS CONDITIONS, SUCH AS OIL AND LIQUID GAS, TOXIC AND AGGRESSIVE CHEMICALS AND VAPOURS. SIEMENS
A5E02545440 CLS300,7ML55062CXX30AB0,8" 150 FLANGE. POINTEK CLS 300,WELDED FLANGE INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT. IT IS IDEAL FOR DETECTING LIQUIDS, SOLIDS, SLURRIES, FOAM AND INTERFACES IN DEMANDING CONDITIONS WHERE HIGH PRESSURE AND TEMPERATURES ARE PRESENT. SIEMENS
A5E02531200 7ML5517-1BE14-2BBX; Y01=1135; Y02=300MM SITRANS LC 500, SINGLE PIECE FLANGED WITH ROD SENSOR INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL AND INTERFACE TRANSMITTER FOR EXTREME AND CRITICAL PROCESS CONDITIONS, SUCH AS OIL AND LIQUID GAS,TOXIC AND AGGRESSIVE CHEMICALS AND VAPOURS. SIEMENS
A5E02528657 7ML55170AK412AB1,CRYO. CERT.,Y15,C12 SITRANS LC 500, SINGLE PIECE FLANGED WITH ROD SENSOR INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL AND INTERFACE TRANSMITTER FOR EXTREME AND CRITICAL PROCESS CONDITIONS, SUCH AS OIL AND LIQUID GAS,TOXIC AND AGGRESSIVE CHEMICALS AND VAPOURS. SIEMENS
A5E02528400 MATERIAL CERTIFICATE 3.1.B SIEMENS
A5E02528052 LOOP CABLE SET SITRANS SL, LENGTH: 25 M SIEMENS
A5E02528048 LOOP CABLE SET SITRANS SL, LENGTH: 10 M SIEMENS
A5E02522098 7ML13011AA112XX0,C12,NACE, Y01=80CM SITRANS LG200 COAXIAL PROBES ARE USED IN MOST STANDARD APPLICATIONS. COAXIAL PROBES YIELD ROBUST SIGNAL STRENGTH EVEN IN EXTREMELY LOW DIELECTRIC APPLICATIONS (DK 1.4 TO 100). SIEMENS
A5E02522081 KIT, EMITTER FOR LR400, PTFE, PTFE, GENERAL PURPOSE, NON PRESSURE SIEMENS
A5E02522036 GASKET KLINGER PSM 15010 / DN50 PN16 SIEMENS
A5E02517895 7ML5510XXD501BA0,XX=1600MM, Y02=500MM POINTEK CLS 300 INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT. IT IS IDEAL FOR DETECTING LIQUIDS,SOLIDS, SLURRIES, FOAM AND INTERFACES IN DEMANDING CONDITIONS WHERE HIGH PRESSURE AND TEMPERATURES ARE PRESENT. SIEMENS
A5E02509347 LOOP CABLE SET SITRANS SL, LENGTH: 5 M SIEMENS
A5E02503870 7ML54250DA003DG0-Z,C12, RF EN1092-1 B1 SITRANS LR 200,FLANGE ADAPTER HORN ANTENNA VERSION 2-WIRE, 6 GHZ PULSE RADAR LEVEL TRANSMITTER FOR CONTINUOUS MONITORING OF LIQUIDS AND SLURRIES IN STORAGE AND PROCESS VESSELS INCLUDING HIGH TEMPERATURE AND PRESSURE, TO A SIEMENS
A5E02502129 7ML5517XXD34BB0 Y01-1335, Y02-300,Y15,C12 SITRANS LC 500, SINGLE PIECE FLANGED WITH ROD SENSOR INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL AND INTERFACE TRANSMITTER FOR EXTREME AND CRITICAL PROCESS CONDITIONS, SUCH AS OIL AND LIQUID GAS,TOXIC AND AGGRESSIVE CHEMICALS AND VAPOURS. SIEMENS
A5E02500683 CLS300,HT(7ML55071AB100BA0), REMOTE 25M POINTEKCLS 300, HIGH TEMPERATURE, THREADED VERSION INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT. IT IS IDEAL FOR DETECTING LIQUIDS, SOLIDS,SLURRIES, FOAM AND INTERFACES IN DEMANDING CONDITIONS WHERE HIGH PRESSURE AND TEMPERATURES ARE PRESENT. SIEMENS
A5E02499247 CLS500(7ML56031EC141AA0Z), ARGON FILLED THERMAL ISOLATOR POINTEK CLS 500 INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH FOR DETECTING INTERFACES, SOLIDS, LIQUIDS, TOXIC AND AGGRESSIVE CHEMICALS IN CRITICAL CONDITIONS OF EXTREME TEMPERATURE AND PRESSURE. SIEMENS
A5E02499246 7ML55172BL442ABXZ,ARGON THERMAL ISOLATOR SITRANS LC 500, SINGLE PIECE FLANGED WITH ROD SENSOR INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL AND INTERFACE TRANSMITTER FOR EXTREME AND CRITICAL PROCESS CONDITIONS, SUCH AS OIL AND LIQUID GAS,TOXIC AND AGGRESSIVE CHEMICALS AND VAPOURS. SIEMENS
A5E02497667 CLS200,7ML55041JD161AA0, Y01=3400,C12,NACE POINTEK CLS 200: WELDED FLANGE VERSATILE INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT, IDEAL FOR DETECTION OF LIQUIDS, SOLIDS,SLURRIES, FOAM AND INTERFACES. SIEMENS
A5E02497666 CLS200,7ML55041HB161AA0, Y01=2112,C12,NACE POINTEK CLS 200: WELDED FLANGE VERSATILE INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT, IDEAL FOR DETECTION OF LIQUIDS, SOLIDS,SLURRIES, FOAM AND INTERFACES. SIEMENS
A5E02497665 CLS200,7ML55041HD161AA0, Y01=3000,C12,NACE POINTEK CLS 200: WELDED FLANGE VERSATILE INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT, IDEAL FOR DETECTION OF LIQUIDS, SOLIDS,SLURRIES, FOAM AND INTERFACES. SIEMENS
A5E02497663 CLS500,7ML56011DA121BA0, Y01=200,C12,NACE POINTEK CLS 500 INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH FOR DETECTING INTERFACES, SOLIDS, LIQUIDS, TOXIC AND AGGRESSIVE CHEMICALS IN CRITICAL CONDITIONS OF EXTREME TEMPERATURE AND PRESSURE. SIEMENS
A5E02497662 CLS200,7ML55041FB161AA0, Y01=220,C12,NACE POINTEK CLS 200: WELDED FLANGE VERSATILE INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT, IDEAL FOR DETECTION OF LIQUIDS, SOLIDS,SLURRIES, FOAM AND INTERFACES. SIEMENS
A5E02497661 CLS200,7ML55040XD161AA0, C12,NACE POINTEK CLS 200: WELDED FLANGE VERSATILE INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT, IDEAL FOR DETECTION OF LIQUIDS, SOLIDS,SLURRIES, FOAM AND INTERFACES. SIEMENS
A5E02496492 CLS300,HT (7ML55071AB100BA1A07), REMOTE VERSION(EXTRA ENCL) WITH 3M CABLE: POINTEKCLS 300, HIGH TEMPERATURE, THREADED VERSION INVERSE FREQUENCY SHIFT CAPACITANCE LEVEL SWITCH WITH OPTIONAL ROD/CABLE CHOICES AND CONFIGURABLE OUTPUT. IT IS IDEAL FOR DETECTING LIQUIDS, SOLIDS,SLURRIES, FOAM AND INTERFACES IN DEMANDING CONDITIONS WHERE HIGH PRESSURE AND TEMPERATURES ARE PRESENT. SIEMENS