7SG1

Артикул Наименование Производитель
7SG1813-...10-0E.0 DIFFERENTIAL RELAY (SOLKOR-N) LINE DIFFERENTIAL FUNCTIONALITY: 3-PHASE OVERCURRENT (50/51) EARTH-FAULT OVERCURR. (50N/51N) 3-PHASE DIFFERENTIAL (WITH FIXED SETTINGS) (87L) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAIL (50BF) EXTERNAL/INTERNAL INTERTRIP(96) VARIABLE DIFFERENTIAL SETTINGS FREQUENCY: 50HZ NOMINAL CURRENT: 1/5A CASE SIZE E8 (4U HIGH) - 7SG1813...100E.0 Siemens
7SG1811-...10-0E.0 DIFFERENTIAL RELAY (SOLKOR-N) LINE DIFFERENTIAL FUNCTIONALITY: 3-PHASE OVERCURRENT (50/51) EARTH-FAULT OVERCURR.(50N/5 1N) 3-PHASE DIFFERENTIAL (WITH FIXED SETTINGS) (87L) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAIL (50BF) CT SUPERVISION EXTERNAL/INTERNAL INTERTRIP(96) FREQUENCY: 50HZ NOMINAL CURRENT: 1/5A CASE SIZE E8 (4U HIGH) - 7SG1811...100E.0 Siemens
7SG1724-.....-..A0 THERMAL PROTECTION (RHO 3) FOUR POLE RELAY, - 7SG1724.......A0 Siemens
7SG1714-.....-..A0 MOTOR PROTECTION (RHO 3) FOUR POLE RELAY - 7SG1714.......A0 Siemens
7SG1643-0...1-1KA0 OHMEGA 408 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) EARTH-FAULT QUADRILAT. CHAR. + SINGLE POLE TRIPPING + DISTANCE SIGNALLING SCHEMA +CURRENT REVERSAL, CB ECHO, WEEK INFEED + THERMAL OVERLOAD NOMINAL CURRENT: 1, 2 OR 5A VOLTAGE INPUTS:63.5/110V AC CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16430...11KA0 Siemens
7SG1643-0...1-1JA0 OHMEGA 408 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) EARTH-FAULT QUADRILAT. CHAR. + SINGLE POLE TRIPPING + DISTANCE SIGNALLING SCHEMA +CURRENT REVERSAL, CB ECHO, WEEK INFEED + THERMAL OVERLOAD NOMINAL CURRENT: 1, 2 OR 5A VOLTAGE INPUTS:63.5/110V AC CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16430...11JA0 Siemens
7SG1643-0...1-1HA0 OHMEGA 408 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) EARTH-FAULT QUADRILAT. CHAR. + SINGLE POLE TRIPPING + DISTANCE SIGNALLING SCHEMA +CURRENT REVERSAL, CB ECHO, WEEK INFEED + THERMAL OVERLOAD NOMINAL CURRENT: 1, 2 OR 5A VOLTAGE INPUTS:63.5/110V AC CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16430...11HA0 Siemens
7SG1643-0...1-1GA0 OHMEGA 408 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) EARTH-FAULT QUADRILAT. CHAR. + SINGLE POLE TRIPPING + DISTANCE SIGNALLING SCHEMA +CURRENT REVERSAL, CB ECHO, WEEK INFEED + THERMAL OVERLOAD NOMINAL CURRENT: 1, 2 OR 5A VOLTAGE INPUTS:63.5/110V AC CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16430...11GA0 Siemens
7SG1642-0...1-1KA0 OHMEGA 406 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) EARTH-FAULT QUADRILAT. CHAR. + SINGLE POLE TRIPPING + LOSS OF LOAD, STUB PROTECT. +CURRENT REVERSAL, CB ECHO, WEEK INFEED + DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO + WEEK INFEED +TWO SHOT 1P/3P AUTO-RECLOSE WITH REACH EXTENSION SCHEME(79) CHECK SYNCHRONISATION CASE SIZE E12 (4U HIGH) VOLTAGE INPUTS:63.5/110V AC CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16420...11KA0 Siemens
7SG1642-0...1-1JA0 OHMEGA 406 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) EARTH-FAULT QUADRILAT. CHAR. + SINGLE POLE TRIPPING + LOSS OF LOAD, STUB PROTECT. +CURRENT REVERSAL, CB ECHO, WEEK INFEED + DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO + WEEK INFEED +TWO SHOT 1P/3P AUTO-RECLOSE WITH REACH EXTENSION SCHEME(79) CHECK SYNCHRONISATION CASE SIZE E12 (4U HIGH) VOLTAGE INPUTS:63.5/110V AC CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16420...11JA0 Siemens
7SG1642-0...1-1HA0 OHMEGA 406 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) EARTH-FAULT QUADRILAT. CHAR. + SINGLE POLE TRIPPING + LOSS OF LOAD, STUB PROTECT. +CURRENT REVERSAL, CB ECHO, WEEK INFEED + DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO + WEEK INFEED +TWO SHOT 1P/3P AUTO-RECLOSE WITH REACH EXTENSION SCHEME(79) CHECK SYNCHRONISATION CASE SIZE E12 (4U HIGH) VOLTAGE INPUTS:63.5/110V AC CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16420...11HA0 Siemens
7SG1642-0...1-1GA0 OHMEGA 406 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) EARTH-FAULT QUADRILAT. CHAR. + SINGLE POLE TRIPPING + LOSS OF LOAD, STUB PROTECT. +CURRENT REVERSAL, CB ECHO, WEEK INFEED + DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO + WEEK INFEED +TWO SHOT 1P/3P AUTO-RECLOSE WITH REACH EXTENSION SCHEME(79) CHECK SYNCHRONISATION CASE SIZE E12 (4U HIGH) VOLTAGE INPUTS:63.5/110V AC CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16420...11GA0 Siemens
7SG1641-0...1-1KA0 OHMEGA 402 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE POLE TRIPPING + STUB PROTECTION NOMINAL CURRENT: 1.2 OR 5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16410...11KA0 Siemens
7SG1641-0...1-1JA0 OHMEGA 402 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE POLE TRIPPING + STUB PROTECTION NOMINAL CURRENT: 1.2 OR 5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16410...11JA0 Siemens
7SG1641-0...1-1HA0 OHMEGA 402 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE POLE TRIPPING + STUB PROTECTION NOMINAL CURRENT: 1.2 OR 5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16410...11HA0 Siemens
7SG1641-0...1-1GA0 OHMEGA 402 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE POLE TRIPPING + STUB PROTECTION NOMINAL CURRENT: 1.2 OR 5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16410...11GA0 Siemens
7SG1635-0...1-1KA0 OHMEGA 315 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS + OVERCURRENT GUARD +BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) + DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16350...11KA0 Siemens
7SG1635-0...1-1JA0 OHMEGA 315 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS + OVERCURRENT GUARD +BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) + DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16350...11JA0 Siemens
7SG1635-0...1-1HA0 OHMEGA 315 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS + OVERCURRENT GUARD +BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) + DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16350...11HA0 Siemens
7SG1635-0...1-1GA0 OHMEGA 315 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS + OVERCURRENT GUARD +BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) + DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16350...11GA0 Siemens
7SG1634-0...1-1KA0 OHMEGA 314 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS +DISTANCE SIGNALLING SCHEMES BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) +DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16340...11KA0 Siemens
7SG1634-0...1-1JA0 OHMEGA 314 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS +DISTANCE SIGNALLING SCHEMES BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) +DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16340...11JA0 Siemens
7SG1634-0...1-1HA0 OHMEGA 314 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS +DISTANCE SIGNALLING SCHEMES BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) +DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16340...11HA0 Siemens
7SG1634-0...1-1GA0 OHMEGA 314 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + FOUR MHO IMPEDANCE ZONES + EARTH-FAULT QUADRILATERAL CHARACTERISTICS +DISTANCE SIGNALLING SCHEMES BLOCKING OVERREACH + DUAL DIRECTIONAL (HIGH IMPEDANCE) EARTH-FAULT (67N) +DIRECT TRIPPING AND PERMISSIVE OVERREACH SCHEMES + BLOCKING SCHEME + CHECK SYNCHRONISING (25) +SENSITIVE EARTH-FAULT (50G) +TWO STAGE DTL UNDERVOLTAGE NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16340...11GA0 Siemens
7SG1633-0...1-1KA0 OHMEGA 311 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16330...11KA0 Siemens
7SG1633-0...1-1JA0 OHMEGA 311 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16330...11JA0 Siemens
7SG1633-0...1-1HA0 OHMEGA 311 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16330...11HA0 Siemens
7SG1633-0...1-1GA0 OHMEGA 311 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16330...11GA0 Siemens
7SG1632-0...1-1KA0 OHMEGA 308 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16320...11KA0 Siemens
7SG1632-0...1-1JA0 OHMEGA 308 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16320...11JA0 Siemens
7SG1632-0...1-1HA0 OHMEGA 308 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16320...11HA0 Siemens
7SG1632-0...1-1GA0 OHMEGA 308 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES + DIRECTIONAL (HIGH IMPEDANCE) EARH-FAULT (67N) +DIRECT TRANSFER TRIPPING AND PERMISSIVE OVERREACH SCHEMES +CURRENT REVERSAL AND CB ECHO +SINGLE SHOT AUTO-RECLOSE WITH REACH EXTENSION SCHEME (79) +CHECK SYNCHRONISING (25) +BROKEN CODUCTOR +CIRCUIT BREAKER FAIL (50BF) NOMINAL CURRENT: 1.2 OR 5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16320...11GA0 Siemens
7SG1631-0...1-1KA0 OHMEGA 305 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES NOMINAL CURRENT: 1, 2 OR 5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E16 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16310...11KA0 Siemens
7SG1631-0...1-1JA0 OHMEGA 305 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES NOMINAL CURRENT: 1.2 OR 5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E16 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16310...11JA0 Siemens
7SG1631-0...1-1HA0 OHMEGA 305 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES NOMINAL CURRENT: 1, 2 OR 5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16310...11HA0 Siemens
7SG1631-0...1-1GA0 OHMEGA 305 RELAY STANDARD FUNCTIONALITY + DISTANCE PROTECTION (21/21N) + THREE MHO IMPEDANCE ZONES NOMINAL CURRENT: 1.2 OR 5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG16310...11GA0 Siemens
7SG1510-2..30-0GA0 TRANSFORMER VOLTAGE CONTROL (MICRO TAPP) AS BASIC MODEL ONLY PARTICULARLY SUITABLE FOR EMBEDDED GENERATION AND TRACTION SYSTEM APPLICATIONS AS THIS MODEL IS CAPABLE OF CONTROLLING THE HV OR LV VOLTAG FREQUENCY: 50/60HZ NOMINAL CURRENT: 1 /5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG15102..300GA0 Siemens
7SG1510-2..30-0EA0 TRANSFORMER VOLTAGE CONTROL (MICRO TAPP) AS BASIC MODEL ONLY PARTICULARLY SUITABLE FOR EMBEDDED GENERATION AND TRACTION SYSTEM APPLICATIONS AS THIS MODEL IS CAPABLE OF CONTROLLING THE HV OR LV VOLTAG FREQUENCY: 50/60HZ NOMINAL CURRENT: 1 /5A CASE SIZE E8 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG15102..300EA0 Siemens
7SG1510-1..30-0GA0 TRANSFORMER VOLTAGE CONTROL (MICRO TAPP) MICROPROCESSOR BASED AUTOMATIC VOLTAGE CONTROL (AVC) SYSTEM OPERATING ON THE WELL PROVEN TAPP PHILOSOPHY FREQUENCY: 50/60HZ NOMINAL CURRENT: 1/5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG15101..300GA0 Siemens
7SG1510-1..30-0EA0 TRANSFORMER VOLTAGE CONTROL (MICRO TAPP) MICROPROCESSOR BASED AUTOMATIC VOLTAGE CONTROLL (AVC) SYSTEM OPERATING ON THE WELL PROVEN TAPP PHIOSOPHY FREQUENCY: 50/60HZ NOMINAL CURRENT: 1/5A CASE SIZE E8 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 - 7SG15101..300EA0 Siemens
7SG145.-0.B.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 5 ANALOGUE INPUT SETS, 11 BINARY INP./ 13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG145.0.B.01.B0 Siemens
7SG145.-0.B.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 5 ANALOGUE INPUT SETS, 11 BINARY INP./ 13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG145.0.B.00.B0 Siemens
7SG145.-0.A.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 5 ANALOGUE INPUT SETS, 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG145.0.A.01.B0 Siemens
7SG145.-0.A.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 5 ANALOGUE INPUT SETS, 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG145.0.A.00.B0 Siemens
7SG144.-0.C.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 4 ANALOGUE INPUT SETS, 19 BINARY INP./ 21 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG144.0.C.01.B0 Siemens
7SG144.-0.C.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 4 ANALOGUE INPUT SETS, 19 BINARY INP/ 21 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG144.0.C.00.B0 Siemens
7SG144.-0.B.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 4 ANALOGUE INPUT SETS, 11 BINARY INP./ 13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG144.0.B.01.B0 Siemens
7SG144.-0.B.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 4 ANALOGUE INPUT SETS, 11 BINARY INP/ 13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG144.0.B.00.B0 Siemens
7SG144.-0.A.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 4 ANALOGUE INPUT SETS, 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG144.0.A.01.B0 Siemens
7SG144.-0.A.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 4 ANALOGUE INPUT SETS, 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG144.0.A.00.B0 Siemens
7SG143.-0.D.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 3 ANALOGUE INPUT SETS, 2 OR 3 WINDINGS 27 BINARY INP/ 29 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG143.0.D.01.B0 Siemens
7SG143.-0.D.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 3 ANALOGUE INPUT SETS, 2 OR 3 WINDINGS 27 BINARY INP./ 29 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG143.0.D.00.B0 Siemens
7SG143.-0.C.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 3 ANALOGUE INPUT SETS, 2 OR 3 WINDINGS 19 BINARY INP/ 21 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG143.0.C.01.B0 Siemens
7SG143.-0.C.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 3 ANALOGUE INPUT SETS, 2 OR 3 WINDINGS 19 BINARY INP./ 21 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG143.0.C.00.B0 Siemens
7SG143.-0.B.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 3 ANALOGUE INPUT SETS, 2 OR 3 WINDINGS 11 BINARY INP/ 13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG143.0.B.01.B0 Siemens
7SG143.-0.B.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 3 ANALOGUE INPUT SETS, 2 OR 3 WINDINGS 11 BINARY INP./ 13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG143.0.B.00.B0 Siemens
7SG143.-0.A.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 3 ANALOGUE INPUT SETS, 2 OR 3 WINDINGS 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG143.0.A.01.B0 Siemens
7SG143.-0.A.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 3 ANALOGUE INPUT SETS, 2 OR 3 WINDINGS 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG143.0.A.00.B0 Siemens
7SG142.-0.D.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 2 ANALOGUE INPUT SETS, 2 WINDING, 27 BINARY INP./ 29 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMIEC 60870-103 OR MODBUS RTU FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG142.0.D.00.B0 Siemens
7SG142.-0.D.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 2 ANALOGUE INPUT SETS, 2 WINDING, 19 BINARY INP./ 21 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG142.0.D.01.B0 Siemens
7SG142.-0.C.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 2 ANALOGUE INPUT SETS, 2 WINDIING, 19 BINARY INP./ 21 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG142.0.C.00.B0 Siemens
7SG142.-0.B.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 2 ANALOGUE INPUT SETS, 2 WINDING, 11 BINARY INP./ 13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG142.0.B.01.B0 Siemens
7SG142.-0.B.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 2 ANALOGUE INPUT SETS, 2 WINDING, 11 BINARY INP./ 13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG142.0.B.00.B0 Siemens
7SG142.-0.A.0-1.B0 TRANSFORMER PROTECTION DUOBIAS-M 2 ANALOGUE INPUT SETS, 2 WINDING, 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG142.0.A.01.B0 Siemens
7SG142.-0.A.0-0.B0 TRANSFORMER PROTECTION DUOBIAS-M 2 ANLOGUE INPUT SETS, 2 WINDING 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A COMMUNICATION INTERFACE: FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG142.0.A.00.B0 Siemens
7SG132.-0..10-1HA0 DELTA FEEDER PROTECTION AND CONTROL (FM1-2XX) FUNCTIONALITY: PHASE FAULT OVERCURRENT (50/51) COLD LOAD PICKUP EARTH-FAULT OVERCURRENT (RESIDUAL CALCULAT. (50N/51N) THERMAL OVERLOAD (49) PHASE UNBALANCE/ BROKEN CONDUCTOR (46) CIRCUIT BREAKER FAIL (50BF) AUTORECLOSE (79) FREQUENCY: 50HZ NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: 63.5/110V AC CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-COONECTOR)/ IEC 60870-5-103 - 7SG132.0..101HA0 Siemens
7SG1312-0..10-1HA0 DELTA FEEDER PROTECTION AND CONTROL (FM1-11X) FUNCTIONALITY: OPTION 12 STANDARD FUNCTIONALITY + EARTH-FAULT OVERCURRENT (MEASURED) (50G/51G) FREQUENCY: 50HZ NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13120..101HA0 Siemens
7SG1312-0..10-0HA0 DELTA FEEDER PROTECTION AND CONTROL (FM1-11X) FUNCTIONALITY: OPTION 12 STANDARD FUNCTIONALITY + EARTH-FAULT OVERCURRENT (MEASURED) (50G/51G) FREQUENCY: 50HZ NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: (NOT AVAILABLE) CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13120..100HA0 Siemens
7SG1311-0..10-1HA0 DELTA FEEDER PROTECTION AND CONTROL (FM1-11X) FUNCTIONALITY: OPTION 11 STANDARD FUNCTIONALITY + SENSITIVE EARTH-FAULT/ RESTRICT EARTH FAULT (50G/87G) FREQUENCY: 50HZ NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13110..101HA0 Siemens
7SG1311-0..10-0HA0 DELTA FEEDER PROTECTION AND CONTROL (FM1-11X) FUNCTIONALITY: OPTION 11 STANDARD FUNCTIONALITY + SENSITIVE EARTH-FAULT/ RESTRICT EARTH FAULT (50G/87G) FREQUENCY: 50HZ NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: (NOT AVAILABLE) CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13110..100HA0 Siemens
7SG1304-0.H.0-1GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 12 STANDARD FUNCTIONALITY + + DIRECTIONAL DETECTION FOR PHASE-FAULT(67),EARTH-F. (67N) 3-PHASE UNDER/OVERVOLTAGE UNDER-/OVER FREQUENCY (61) NEUTRAL VOLT. DISPLACEM (59N) NPS OVERVOLTAGE (47) AUTORECLOSE (79) 27 BINARY INPUTS/13 BINARY OUTP (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13040.H.01GB0 Siemens
7SG1304-0.C.0-1GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 12 STANDARD FUNCTIONALITY + + DIRECTIONAL DETECTION FOR PHASE-FAULT(67),EARTH-F. (67N) 3-PHASE UNDER/OVERVOLTAGE UNDER-/OVER FREQUENCY (61) NEUTRAL VOLT. DISPLACEM (59N) NPS OVERVOLTAGE (47) AUTORECLOSE (79) 19 BINARY INPUTS/21 BINARY OUTP (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13040.C.01GB0 Siemens
7SG1304-0.B.0-1GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 12 STANDARD FUNCTIONALITY + + DIRECTIONAL DETECTION FOR PHASE-FAULT(67),EARTH-F. (67N) 3-PHASE UNDER/OVERVOLTAGE UNDER-/OVER FREQUENCY (61) NEUTRAL VOLT. DISPLACEM (59N) NPS OVERVOLTAGE (47) AUTORECLOSE (79) 11BINARY INPUTS/13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13040.B.01GB0 Siemens
7SG1304-0.A.0-1EB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 12 STANDARD FUNCTIONALITY + + DIRECTIONAL DETECTION FOR PHASE-FAULT(67),EARTH-F. (67N) 3-PHASE UNDER/OVERVOLTAGE UNDER-/OVER FREQUENCY (61) NEUTRAL VOLT. DISPLACEM (59N) NPS OVERVOLTAGE (47) AUTORECLOSE (79) 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E 8 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13040.A.01EB0 Siemens
7SG1303-0.H.0-1GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 11 STANDARD FUNCTIONALITY + DIRECTIONAL DETECTION FOR PHASE-FAULT(67),EARTH-F. (67N) 3-PHASE UNDER/OVERVOLTAGE UNDER-/OVER FREQUENCY (61) NEUTRAL VOLT. DISPLACEM (59N) NPS OVERVOLTAGE (47) VT SUPERVISION (74VT) 27 BINARY INPUTS/13 BINARY OUTP (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13030.H.01GB0 Siemens
7SG1303-0.C.0-1GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 11 STANDARD FUNCTIONALITY + DIRECTIONAL DETECTION FOR PHASE-FAULT(67),EARTH-F. (67N) 3-PHASE UNDER/OVERVOLTAGE UNDER-/OVER FREQUENCY (61) NEUTRAL VOLT. DISPLACEM (59N) NPS OVERVOLTAGE (47) VT SUPERVISION (74VT) 19 BINARY INPUTS/21 BINARY OUTP (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13030.C.01GB0 Siemens
7SG1303-0.B.0-1GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 11 STANDARD FUNCTIONALITY + DIRECTIONAL DETECTION FOR PHASE-FAULT(67),EARTH-F. (67N) 3-PHASE UNDER/OVERVOLTAGE UNDER-/OVER FREQUENCY (61) NEUTRAL VOLT. DISPLACEM (59N) NPS OVERVOLTAGE (47) VT SUPERVISION (74VT) 11BINARY INPUTS/13 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13030.B.01GB0 Siemens
7SG1303-0.A.0-1EB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 11 STANDARD FUNCTIONALITY + DIRECTIONAL DETECTION FOR PHASE-FAULT(67),EARTH-F. (67N) 3-PHASE UNDER/OVERVOLTAGE UNDER-/OVER FREQUENCY (61) NEUTRAL VOLT. DISPLACEM (59N) NPS OVERVOLTAGE (47) VT SUPERVISION (74VT) 3 BINARY INPUTS/ 5 BINARY OUTP. (INCL. 3 CHANGEOVER) NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E8 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13030.A.01EB0 Siemens
7SG1302-0.C.0-1GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 06 STANDARD FUNCTIONALITY + AUTORECLOSURE 19 BINARY INPUTS/21 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13020.C.01GB0 Siemens
7SG1302-0.C.0-0GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 06 STANDARD FUNCTIONALITY + AUTORECLOSURE 19 BINARY INPUTS/21 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: (NOT AVAILABLE) CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13020.C.00GB0 Siemens
7SG1302-0.B.0-1EB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 06 STANDARD FUNCTIONALITY + AUTORECLOSURE 11 BINARY INPUTS/13 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E8 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13020.B.01EB0 Siemens
7SG1302-0.B.0-0EB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 06 STANDARD FUNCTIONALITY + AUTORECLOSURE 11 BINARY INPUTS/13 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: (NOT AVAILABLE) CASE SIZE E8 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13020.B.00EB0 Siemens
7SG1301-0.H.0-0GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 05 STANDARD FUNCTIONALITY 22 BINARY INPUTS/13 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: (NOT AVAILABLE) CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13010.H.00GB0 Siemens
7SG1301-0.C.0-1GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 05 STANDARD FUNCTIONALITY 19 BINARY INPUTS/21 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13010.C.01GB0 Siemens
7SG1301-0.C.0-0GB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 05 STANDARD FUNCTIONALITY 19 BINARY INPUTS/21 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: (NOT AVAILABLE) CASE SIZE E12 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13010.C.00GB0 Siemens
7SG1301-0.B.0-1EB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 05 STANDARD FUNCTIONALITY 11 BINARY INPUTS/13 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E8 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13010.B.01EB0 Siemens
7SG1301-0.B.0-0EB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 05 STANDARD FUNCTIONALITY 11 BINARY INPUTS/13 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: (NOT AVAILABLE) CASE SIZE E8 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13010.B.00EB0 Siemens
7SG1301-0.A.0-1EB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 05 STANDARD FUNCTIONALITY 3 BINARY INPUTS/ 5 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS 63.5/110V AC CASE SIZE E8 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13010.A.01EB0 Siemens
7SG1301-0.A.0-0EB0 DELTA FEEDER PROTECTION AND CONTROL (FM0-00X) FUNCTIONALITY: OPTION 05 STANDARD FUNCTIONALITY 3 BINARY INPUTS/ 5 BINARY OUTP (INCL. 3 CHANGEOVER NOMINAL CURRENT: 1/5A VOLTAGE INPUTS: (NOT AVAILABLE) CASE SIZE E8 (4U HIGH) COMMUNUCATION INTERFACE FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG13010.A.00EB0 Siemens
7SG1211-0...0-0HB0 DAD-N HIGH IMPEDANCE OR CIRCULATING CURRENT PROTECTION WITH INTEGRAL CURRENT TRANSF. SUPERVISION AND COMMUNICATIONS USING IEC 60870-5-103 PROTOCOL OVERALL DIFFERENTIAL (87/50-1,87/50-2) NOMINAL CURRENT: 1/5A CASE SIZE E12 (4U WIDE) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG12110...00HB0 Siemens
7SG1211-0...0-0GB0 DAD-N HIGH IMPEDANCE OR CIRCULATING CURRENT PROTECTION WITH INTEGRAL CURRENT TRANSF. SUPERVISION AND COMMUNICATIONS USING IEC60870-5-103 PROTOCOL OVERALL DIFFERENTIAL (87/50-1,87/50-2) NOMINAL CURRENT: 1/5A CASE SIZE E12 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG12110...00GB0 Siemens
7SG1211-0...0-0EB0 DAD-N - HIGH IMPEDANCE OR CIRCULATING CURRENT PROTECTION WITH INTEGRAL CURRENT TRANSF. SUPERVISION AND COMMUNICATIONS USING IEC60870-5-103 PROTOCOL OVERALL DIFFERENTIAL (87/50-1, 87/50-2) NOMINAL CURRENT: 1/5A CASE SIZE E8 (4U HIGH) FIBRE OPTIC (ST-CONNECTOR)/ IEC 60870-5-103 OR MODBUS RTU - 7SG12110...00EB0 Siemens
7SG1183-.....-0DA0 VOLTAGE/FREQUENCY RELAY(ARGUS8) THREE POLE RELAY, CASE SIZE E6 (4U HIGH) - 7SG1183.....0DA0 Siemens
7SG1182-.....-0CA0 VOLTAGE/FREQUENCY RELAY(ARGUS8) TWO POLE RELAY, CASE SIZE E4 (4U HIGH) - 7SG1182.....0CA0 Siemens
7SG1172-.....-0CA0 CHECK- AND SYSTEM SYNCHRONISING RELAY (ARGUS 7) TWO POLE RELAY CASE SIZE E4 (4U HIGH) - 7SG1172.....0CA0 Siemens
7SG1164-.Q...-..A0 DIRECTIONAL O/C RELAY WITH AUTO-RECLOSE (ARGUS 6) FOUR POLE RELAY 3 POLE PHASE-FAULT AND EARTH-FAULT DIRECTIONAL - 7SG1164.Q.....A0 Siemens
7SG1164-.P...-..A0 DIRECTIONAL O/C RELAY WITH AUTO-RECLOSE (ARGUS 6) FOUR POLE RELAY 3 POLE PHASE-FAULT DIRECTIONAL AND EARTH-FAULT DIRECTIONAL OR 3 POLE PHASE-FAULT DIRECTIONAL AND EARTH-FAULT - 7SG1164.P.....A0 Siemens
7SG1164-.N...-..A0 DIRECTIONAL O/C RELAY WITH AUTO-RECLOSE (ARGUS 6) FOUR POLE RELAY 3 POLE PHASE-FAULT DIRECTIONAL AND SENSITIVE/RESTRICTED EARTH- FAULT (SEF/REF) - 7SG1164.N.....A0 Siemens
7SG1144-.....-0DA0 NONDIRECTIONAL O/C RELAY WITH AUTO-RECLOSE (ARGUS 4) FOUR POLE RELAY, CASE SIZE E6 (4U HIGH) - 7SG1144.....0DA0 Siemens
7SG1125-.S...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2 - 500) FOUR POLE RELAY (NUMERIC VT) 3 POLE PHASE-FAULT DIRECTIONAL AND SENSITIVE/RESTRICTED EARTH-FAULT (SEF/REF) OR 2 POLE PHASE-FAULT DIRECTIONAL AND EARTH FAULT DIRECTIONAL AND SENSITIVE/RESTRICTED EARTH-FAULT (SEF/REF) - 7SG1125.S.....A0 Siemens
7SG1125-.R...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2 - 500) FOUR POLE RELAY (NUMERIC VT) 3 POLE PHASE-FAULT DIRECTIONAL AND EARTH-FAULT DIRECTIONAL - 7SG1125.R.....A0 Siemens
7SG1124-.Q...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2) FOUR POLE RELAY 3 POLE PHASE-FAULT AND EARTH-FAULT DIRECTIONAL - 7SG1124.Q.....A0 Siemens
7SG1124-.P...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2) FOUR POLE RELAY 3 POLE PHASE-FAULT DIRECTIONAL AND EARTH-FAULT DIRECTIONAL OR 3 POLE PHASE-FAULT DIRECTIONAL AND EARTH-FAULT - 7SG1124.P.....A0 Siemens
7SG1124-.N...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2) FOUR POLE RELAY 3 POLE PHASE-FAULT DIRECTIONAL AND SENSITIVE/RESTRICTED EARTH- FAULT (SEF/REF) - 7SG1124.N.....A0 Siemens
7SG1123-.M...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2) THREE POLE RELAY 2 POLE PHASE-FAULT AND EARTH-FAULT DIRECTIONAL - 7SG1123.M.....A0 Siemens
7SG1123-.L...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2) THREE POLE RELAY 2 POLE PHASE-FAULT DIRECTIONAL AND EARTH-FAULT DIRECTIONAL OR 2 POLE PHASE-FAULT DIRECTIONAL AND EARTH-FAULT - 7SG1123.L.....A0 Siemens
7SG1123-.K...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2) THREE POLE RELAY 2 POLE PHASE-FAULT DIRECTIONAL AND SENSITVE/RESTRICTED EARTH-FAULT (SEF/REF) - 7SG1123.K.....A0 Siemens
7SG1123-.J...-..A0 DIRECTIONAL O/C RELAY (ARGUS 2) THREE POLE RELAY 3 POLE PHASE-FAULT DIRECTIONAL - 7SG1123.J.....A0 Siemens
7SG1121-.....-..A0 DIRECTIONAL O/C RELAY (ARGUS 2) SINGLE POLE RELAY CASE SIZE E4 (4U HIGH) - 7SG1121.......A0 Siemens
7SG1115-.....-0CA0 NONDIRECT. O/C RELAY (ARGUS 1 FIXED I/O) FOUR POLE RELAY (FIXED I/O) CASE SIZE E4 (4U HIGH) - 7SG1115.....0CA0 Siemens
7SG1114-.....-0DA0 NONDIRECT. O/C RELAY (ARGUS 1) FOUR POLE RELAY CASE SIZE E6 (4U HIGH) - 7SG1114.....0DA0 Siemens
7SG1113-.....-0DA0 NONDIRECT. O/C RELAY (ARGUS 1) THREE POLE RELAY CASE SIZE E6 (4U HIGH) - 7SG1113.....0DA0 Siemens
7SG1111-.....-0CA0 NONDIRECT. O/C RELAY (ARGUS 1) SINGLE POLE RELAY CASE SIZE E4 (4U HIGH) - 7SG1111.....0CA0 Siemens