6MD20

Артикул Наименование Производитель
6MD2021-0....-1AA0 6MD2021-0....-1AA0 Siemens
6MD2021-0....-2AA4 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS WITH HOUSING, MOUNTING PARTS VERSION V2.4 Siemens
6MD2021-0....-2AA0 6MD2021-0....-2AA0 Siemens
6MD2021-0....-2AA5 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, SINAUT 8-FW. CONNECTION OF PROTECT.DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS WITH HOUSING, MOUNTING PARTS VERSION V2.51 Siemens
6MD2021-0....-2AA1 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS WITH HOUSING, MOUNTING PARTS VERSION V2.1 Siemens
6MD2021-0....-2AA6 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, SINAUT 8-FW. CONNECTION OF PROTECT.DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS WITH HOUSING, MOUNTING PARTS VERSION V2.60 Siemens
6MD2021-0....-2AA2 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS WITH HOUSING, MOUNTING PARTS VERSION V2.2 Siemens
6MD2021-0....-2AB4 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS WITH HOUSING, MOUNTING PARTS VERSION V2.4 WITH TG800 RADIO MODE LICENSE Siemens
6MD2021-0....-2AA3 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS WITH HOUSING, MOUNTING PARTS VERSION V2.3 Siemens
6MD2022-.....-2AA0 6MD2022-.....-2AA0 Siemens
6MD2022-.....-1AA0 6MD2022-.....-1AA0 Siemens
6MD2022-.....-2AA4 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.4 Siemens
6MD2022-.....-2AA5 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, SINAUT 8-FW. CONNECTION OF PROTECT.DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.51 Siemens
6MD2022-.....-2AA1 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.1 Siemens
6MD2022-.....-2AA2 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.2 Siemens
6MD2022-.....-2AB4 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.4 WITH TG800 RADIO MODE LICENSE Siemens
6MD2022-.....-2AA3 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 12 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: COMPLETE PACKAGE VERSION V2.3 Siemens
6MD2030-0..0.-1AA0 TELECONTROL UNIT SICAM MICRORTU BASED ON: AUTOMATION SYSTEM S7-224 OR S7-226 TELECONTROL PROTOCOL: IEC 60870-5-101,UNBALANCED MODE MAX. 16 DOUBLE-POINT INFORMAT., THEREOF 7 OR 12 MONITORED MAX. 32 SINGLE-POINT INFORMAT., THEREOF 14 OR 24 MONITORED ACQUISATION WITH 10MS SCAN MAX. 4 METERED VALUES MAX. 32 SINGLE COMMANDS, THEREOF 8 OR 10 MONITORED MAX. 16 DOUBLE-COMMANDS, THEREOF 4 OR 5 MONITORED MAX. 16 MEASURED VALUES INSULATION: 500V MEASURED VALUES NON-ISOLATED SUPPLIED IN INDIVIDUAL PARTS PROGRAM VERSION V1.00 Siemens
6MD2020-0....-2AA0 6MD2020-0....-2AA0 Siemens
6MD2030-0..0.-1BA0 TELECONTROL UNIT SICAM MICRORTU BASED ON: AUTOMATION SYSTEM S7-224 OR S7-226 TELECONTROL PROTOCOL: IEC 60870-5-101,UNBALANCED MODE MAX. 16 DOUBLE-POINT INFORMAT., THEREOF 7 OR 12 MONITORED MAX. 32 SINGLE-POINT INFORMAT., THEREOF 14 OR 24 MONITORED ACQUISATION WITH 10MS SCAN MAX. 4 METERED VALUES MAX. 32 SINGLE COMMANDS, THEREOF 8 OR 10 MONITORED MAX. 16 DOUBLE-COMMANDS, THEREOF 4 OR 5 MONITORED MAX. 16 MEASURED VALUES INSULATION: 500V MEASURED VALUES NON-ISOLATED SUPPLIED IN INDIVIDUAL PARTS PROGRAM VERSION V1.10 Siemens
6MD2020-0....-1AA0 6MD2020-0....-1AA0 Siemens
6MD2020-0....-2AA4 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS VERSION V2.4 Siemens
6MD2020-0....-2AA1 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS VERSION V2.1 Siemens
6MD2020-0....-2AA5 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, SINAUT 8-FW. CONNECTION OF PROTECT.DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS VERSION V2.51 Siemens
6MD2020-0....-2AA3 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS VERSION V2.3 Siemens
6MD2020-0....-2AA2 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS VERSION V2.2 Siemens
6MD2031-0..0.-1BA0 TELECONTROL UNIT SICAM MICRORTU BASED ON: AUTOMATION SYSTEM S7-224 OR S7-226 TELECONTROL PROTOCOL: IEC 60870-5-101,UNBALANCED MODE MAX. 16 DOUBLE-POINT INFORMAT., THEREOF 7 OR 12 MONITORED MAX. 32 SINGLE-POINT INFORMAT., THEREOF 14 OR 24 MONITORED ACQUISATION WITH 10MS SCAN MAX. 4 METERED VALUES MAX. 32 SINGLE COMMANDS, THEREOF 8 OR 10 MONITORED MAX. 16 DOUBLE-COMMANDS, THEREFORE 4 OR 5 MONITORED MAX. 16 MEASURED VALUES INSULATION: 500V MEASURED VALUES NON-ISOLATED SYSTEM, ADDITIONALLY WITH HOUSING AND BUILT-IN COMPONENTS Siemens
6MD2020-0....-2AB4 TELECONTROL UNIT SICAM MINIRTU BASIS:AUTOMAT.SYSTEM S7-224/226 INCL. TCM MODULE FOR COMMUNICATION TO CONTROL CENTER TELECONTROL PROTOCOLS IEC 60870-5-101, DNP3.0, TG800, CONNECTION OF PROTECTION DEVICES VIA 60870-5-103 INTEGRATED V.21-MODEM MAX. 192 SINGLE-POINT INDICAT., TIME TAG 10 MS, MAX. 24 METERED VALUES, MAX 192 SINGLE COMMANDS MAX. 48 MEASURED VALUES, MAX. 21 ANALOG OUTPUTS, AUTOMAT. FUNCTIONS PROGRAMMABLE MEASURED VALUES NON-ISOLATED DELIVERY FORM: PARTS VERSION V2.4 WITH TG800 RADIO MODE LICENSE Siemens
6MD2031-0..0.-1AA0 TELECONTROL UNIT SICAM MICRORTU BASED ON: AUTOMATION SYSTEM S7-224 OR S7-226 TELECONTROL PROTOCOL: IEC 60870-5-101,UNBALANCED MODE MAX. 16 DOUBLE-POINT INFORMAT., THEREOF 7 OR 12 MONITORED MAX. 32 SINGLE-POINT INFORMAT., THEREOF 14 OR 24 MONITORED ACQUISATION WITH 10MS SCAN MAX. 4 METERED VALUES MAX. 32 SINGLE COMMANDS, THEREOF 8 OR 10 MONITORED MAX. 16 DOUBLE-COMMANDS, THEREFORE 4 OR 5 MONITORED MAX. 16 MEASURED VALUES INSULATION: 500V MEASURED VALUES NON-ISOLATED SYSTEM, ADDITIONALLY WITH HOUSING AND BUILT-IN COMPONENTS Siemens