6ES7 131-1BH01-0XB0

6ES7 131-1BL01-0XB0

Supply voltages

 

 

Rated value

 

 

  • 24 V DC

Yes

Yes

  • Reverse polarity protection

Yes

Yes

Hardware configuration

 

 

Rack

 

 

  • Required terminal block

TB 16L

TB 32L

Connection method

 

 

Inputs/outputs

Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection

Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection

PROFIBUS DP

 

 

Transmission rate, max.

1.5 Mbit/s

1.5 Mbit/s

Direct data exchange (slave-to-slave communication)

Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC)

Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC)

Digital inputs

 

 

Number of digital inputs

16

32

Input voltage

 

 

  • Rated value, DC

24 V

24 V

  • for signal "0"

-30 to +5 V

-30 to +5 V

  • for signal "1"

13 to 30 V

13 to 30 V

Input current

 

 

  • for signal "1", typ.

5 mA

5 mA

Input delay (for rated value of input voltage)

 

 

  • for standard inputs

 

 

    • at "0" to "1", min.

2 ms

2 ms

    • at "0" to "1", max.

4.5 ms

4.5 ms

Cable length

 

 

  • Cable length for NAMUR input, shielded, max.

1 000 m

1 000 m

Galvanic isolation

 

 

between PROFIBUS DP and all other circuit components

Yes

Yes

Galvanic isolation digital inputs

 

 

  • between the channels

No

No

  • between the channels and PROFIBUS DP

Yes

Yes

Environmental requirements

 

 

Operating temperature

 

 

  • horizontal installation, min.

0 °C

0 °C

  • horizontal installation, max.

60 °C; 40°C for other mountings

60 °C; 40°C for other mountings

Air pressure

 

 

  • permissible range, min.

795 hPa

795 hPa

  • permissible range, max.

1 080 hPa

1 080 hPa

Relative humidity

 

 

  • Operation, min.

5 %

5 %

  • Operation, max.

95 %; RH class 2 in accordance with IEC 1131-2

95 %; RH class 2 in accordance with IEC 1131-2

Vibrations

 

 

  • Operation, checked according to IEC 60068-2-6

Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)

Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)

Shock test

 

 

  • checked according to IEC 60068-2-27

Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms

Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms

Degree of protection

 

 

IP20

Yes

Yes

Dimensions and weight

 

 

Dimensions

 

 

  • Width

145 mm

145 mm

  • Height

60 mm

60 mm

  • Depth

60.5 mm

60.5 mm


 

6ES7 132-1BH00-0XB0

6ES7 132-1BL00-0XB0

Supply voltages

 

 

Rated value

 

 

  • 24 V DC

Yes

Yes

  • Reverse polarity protection

Yes

Yes

Mains buffering, min.

20 ms

20 ms

Load voltage 2L+

 

 

  • Rated value (DC)

24 V; 1L+, 2L+, 3L+

24 V; 1L+, 2L+, 3L+

Current consumption

 

 

from load voltage L1 (without load), max.

50 mA; per load group (L1+ or L2+ / L3+)

100 mA; per load group (L1+ or L2+ / L3+)

from supply voltage L+, max.

70 mA; L4+ / L5+

70 mA; L4+ / L5+

Power losses

 

 

Power loss, typ.

5 W

7 W

Hardware configuration

 

 

Rack

 

 

  • Required terminal block

TB 16L

TB 32L

Communication functions

 

 

Bus protocol/transmission protocol

PROFIBUS DP

PROFIBUS DP

Connection method

 

 

Inputs/outputs

Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection

Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection

PROFIBUS DP

 

 

Transmission rate, max.

1.5 Mbit/s

1.5 Mbit/s

SYNC capability

Yes

Yes

Direct data exchange (slave-to-slave communication)

Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC)

Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC)

Digital outputs

 

 

Number of digital outputs

16

32

Short-circuit protection

Yes; Electronic

Yes; Electronic

Response threshold, typ.

0.7 A

0.7 A

Limitation of inductive shutdown voltage to

typ. (L1+ or L2+ / L3+) -55 V

typ. (L1+ or L2+ / L3+) -55 V

Lamp load, max.

5 W

5 W

Controlling a digital input

Yes

Yes

Output voltage

 

 

  • Rated value (DC)

24 V

24 V

  • for signal "1", min.

Ua - 3 V

Ua - 3 V

Output current

 

 

  • for signal "1" rated value

0.5 A

0.5 A

  • for signal "1" permissible range for 0 to 60 °C, max.

0.5 A

0.5 A

  • for signal "0" residual current, max.

1 mA

1 mA

Output delay with resistive load

 

 

  • 0 to "1", max.

50 ms

50 ms

  • 1 to "0", max.

200 ms

200 ms

Parallel switching of 2 outputs

 

 

  • for increased power

No

No

  • for redundant control of a load

Yes; only outputs of the same group

Yes; only outputs of the same group

Switching frequency

 

 

  • with resistive load, max.

100 Hz

100 Hz

  • with inductive load, max.

0.5 Hz

0.5 Hz

  • on lamp load, max.

8 Hz

8 Hz

Aggregate current of outputs (per group)

 

 

  • all other mounting positions

 

 

    • up to 40 °C, max.

2 A

2 A

  • up to 60 °C, max.

4 A

4 A

  • horizontal arrangement, up to 40 °C, max.

3 000 mA

3 000 mA

  • horizontal arrangement, up to 60 °C, max.

2 000 mA

2 000 mA

Load resistance range

 

 

  • lower limit

41 Ω

41 Ω

  • upper limit

28 000 Ω

28 000 Ω

Cable length

 

 

  • Cable length, shielded, max.

1 000 m

1 000 m

  • Cable length unshielded, max.

600 m

600 m

Interrupts/diagnostics/status information

 

 

Alarms

 

 

  • Alarms

No

No

Diagnoses

 

 

  • Diagnostic functions

Yes

Yes

Diagnostics indication LED

 

 

  • Bus fault BF (red)

Yes

Yes

  • Status indicator digital output (green)

Yes

Yes

  • Status indicator digital input (green)

Yes

Yes

  • Monitoring 24 V voltage supply ON (green)

Yes

Yes

Isolation

 

 

Isolation checked with

500 VDC

500 VDC

Galvanic isolation

 

 

between PROFIBUS DP and all other circuit components

Yes

Yes

Galvanic isolation digital outputs

 

 

  • between the channels

No

No

  • between the channels and PROFIBUS DP

Yes; Optocoupler

Yes

Environmental requirements

 

 

Operating temperature

 

 

  • horizontal installation, min.

0 °C

0 °C

  • horizontal installation, max.

60 °C; 40°C for other mountings

60 °C; 40°C for other mountings

Air pressure

 

 

  • permissible range, min.

795 hPa

795 hPa

  • permissible range, max.

1 080 hPa

1 080 hPa

Relative humidity

 

 

  • Operation, min.

5 %

5 %

  • Operation, max.

95 %; RH class 2 in accordance with IEC 1131-2

95 %; RH class 2 in accordance with IEC 1131-2

Vibrations

 

 

  • Operation, checked according to IEC 60068-2-6

Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)

Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)

Shock test

 

 

  • checked according to IEC 60068-2-27

Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms

Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms

Degree of protection

 

 

IP20

Yes

Yes

General information

 

 

Vendor identification (VendorID)

0016h

0011h

Dimensions and weight

 

 

Dimensions

 

 

  • Width

145 mm

145 mm

  • Height

60 mm

60 mm

  • Depth

60.5 mm

60.5 mm

Weight

 

 

  • Weight, approx.

130 g

150 g


 

6ES7 133-1BL01-0XB0

Supply voltages

 

Rated value

 

  • 24 V DC

Yes

  • Reverse polarity protection

Yes

Hardware configuration

 

Rack

 

  • Required terminal block

TB 32L

Connection method

 

Inputs/outputs

Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection

PROFIBUS DP

 

Transmission rate, max.

1.5 Mbit/s

Direct data exchange (slave-to-slave communication)

Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC)

Digital inputs

 

Number of digital inputs

16

Input voltage

 

  • Rated value, DC

24 V

  • for signal "0"

-30 to +5 V

  • for signal "1"

13 to 30 V

Input current

 

  • for signal "1", typ.

5 mA

Input delay (for rated value of input voltage)

 

  • for standard inputs

 

    • at "0" to "1", min.

2 ms

    • at "0" to "1", max.

4.5 ms

Cable length

 

  • Cable length for NAMUR input, shielded, max.

1 000 m

Digital outputs

 

Number of digital outputs

16

Short-circuit protection

Yes; Electronic

Output voltage

 

  • Rated value (DC)

24 V

  • for signal "1", min.

Ua - 3 V

Output current

 

  • for signal "1" permissible range for 0 to 60 °C, max.

0.5 mA

  • for signal "0" residual current, max.

1 mA

Switching frequency

 

  • with resistive load, max.

100 Hz

  • with inductive load, max.

0.5 Hz

  • on lamp load, max.

8 Hz

Aggregate current of outputs (per group)

 

  • up to 60 °C, max.

4 A

Cable length

 

  • Cable length, shielded, max.

1 000 m

Galvanic isolation

 

between PROFIBUS DP and all other circuit components

Yes

Galvanic isolation digital inputs

 

  • between the channels

No

  • between the channels and PROFIBUS DP

Yes

Environmental requirements

 

Operating temperature

 

  • horizontal installation, min.

0 °C

  • horizontal installation, max.

60 °C; 40°C for other mountings

Air pressure

 

  • permissible range, min.

795 hPa

  • permissible range, max.

1 080 hPa

Relative humidity

 

  • Operation, min.

5 %

  • Operation, max.

95 %; RH class 2 in accordance with IEC 1131-2

Vibrations

 

  • Operation, checked according to IEC 60068-2-6

Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)

Shock test

 

  • checked according to IEC 60068-2-27

Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms

Degree of protection

 

IP20

Yes

Dimensions and weight

 

Dimensions

 

  • Width

145 mm

  • Height

60 mm

  • Depth

60.5 mm


 

6ES7 193-1CH00-0XA0

6ES7 193-1CH10-0XA0

6ES7 193-1CH20-0XA0

6ES7 193-1CL00-0XA0

6ES7 193-1CL10-0XA0

Dimensions and weight

 

 

 

 

 

Dimensions

 

 

 

 

 

  • Width

145 mm

145 mm

191 mm

191 mm

191 mm

  • Height

100 mm; Height with electronics block from top edge of DIN rail (with bus connector 6ES7 972-0CA30-0XA0): 82 mm

100 mm; Height with electronics block from top edge of DIN rail (with bus connector 6ES7 972-0CA30-0XA0): 82 mm

100 mm; Height with electronics block from top edge (with bus connector ): 98.5 mm

100 mm; Height with electronics block from top edge of DIN rail (with bus connector 6ES7 972-0CA30-0XA0): 82 mm

100 mm; Height with electronics block from top edge of DIN rail (with bus connector 6ES7 972-0CA30-0XA0): 82 mm

  • Depth

40.5 mm

40.5 mm

40.5 mm

40.5 mm

40.5 mm

Weight

 

 

 

 

 

  • Weight, approx.

230 g

230 g

283 g

350 g

350 g