6ES7 138-4GA00-0AB0 |
Supply voltages |
|
Load voltage L+ |
|
|
24 V; From power module |
|
Yes |
Current consumption |
|
from load voltage L+ (without load), max. |
300 mA |
Power losses |
|
Power loss, typ. |
0.85 W |
Digital inputs |
|
Number of digital inputs |
4 |
Cable length |
|
|
50 m |
|
50 m |
Analog inputs |
|
Cycle time (all channels) max. |
3.24 ms |
Encoder |
|
Connectable encoders |
|
|
Photoelectric proximity switches with IQ-SENSE |
Interrupts/diagnostics/status information |
|
Diagnoses |
|
|
Yes; Diagnostic information readable |
Diagnostics indication LED |
|
|
Yes |
|
Yes |
Isolation |
|
Isolation checked with |
500 VDC |
Galvanic isolation |
|
Galvanic isolation digital inputs |
|
|
No |
|
Yes |
Permissible potential difference |
|
between different circuits |
75 VDC / 60 VAC |
Dimensions and weight |
|
Dimensions |
|
|
15 mm |
|
81 mm |
|
52 mm |
Weight |
|
|
35 g |
|
6ES7 338-7XF00-0AB0 |
Supply voltages |
|
Load voltage L+ |
|
|
24 V |
Current consumption |
|
from load voltage L+ (without load), max. |
1 A |
from backplane bus 5 V DC, max. |
150 mA; typically |
Connection method |
|
required front connector |
20-pin |
Digital inputs |
|
Number of digital inputs |
8 |
Cable length |
|
|
50 m |
Encoder |
|
Connectable encoders |
|
|
photoelectronic proximity switches and ultrasonic sensors with IQ-Sense, cycle time 2.88 to 6 ms |
Interrupts/diagnostics/status information |
|
Diagnostics indication LED |
|
|
Yes |
Isolation |
|
Isolation checked with |
500 VDC |
Galvanic isolation |
|
Galvanic isolation digital inputs |
|
|
No |
|
Yes |
Dimensions and weight |
|
Dimensions and weight |
|
|
40 mm |
|
125 mm |
|
120 mm |
Weight |
|
|
250 g |