Bestell-Nr.

6GK1 561-3FA00

Product type designation

CP 5613 FO

Transmission rate

 

Transmission rate at interface 1 in accordance with PROFIBUS

9.6 Kbit/s … 12 Mbit/s

Interfaces

 

Number of optical connections at interface 1 in accordance with PROFIBUS

2

Number of electrical connections for power supply

1

Design of optical connection at interface 1 in accordance with PROFIBUS

2x duplex sockets (FO)

Design of electrical connection

 

  • of backplane bus

PCI (32 bit 5 V)

  • for power supply

Low-voltage socket for hollow plug 3.5 mm (-) / 1.3 mm (+)

Supply voltage, current consumption, power loss

 

Type of power supply

DC

Type of power supply: optional external supply

Yes

Power supply

 

  • 1 from backplane bus

5 V

  • 2 from backplane bus

12 V

  • External

9 … 12 V

Relative symmetrical tolerance

 

  • At 5 V with DC

5 %

  • At 12 V with DC

5 %

Current consumed

 

  • Max. 1 from backplane bus with DC

1.4 A

  • Max. 2 from backplane bus with DC

0.3 A

  • Maximum from external power supply with 12 V DC

0.4 A

Effective power loss

7 W

Permitted ambient conditions

 

Ambient temperature

 

  • During operating phase

5 … 60 °C

  • During storage

-40 … +70 °C

  • During transport

-40 … +70 °C

Relative humidity at 25 °C without condensation during operating phase, maximum

80 %

IP degree of protection

IP00

Design, dimensions and weights

 

Module format

PCI

Width

18 mm

Height

107 mm

Depth

168 mm

Net weight

250 g

Product properties, functions, componentsGeneral

 

Number of plug-in cards of same design which can be inserted per PC station

4

Number of modules - Note

-

Cable length

 

  • With polymer cladded fiber cable, maximum

-

  • With plastic optical fiber cable, maximum

50 m

Performance data

 

Performance dataOpen communication

 

Software required for open communication by means of SEND/RECEIVE

FDL driver included in scope of delivery of CP

Number of possible connections for open communication by means of SEND/RECEIVE, maximum

80

Performance data for PROFIBUS DP master

 

Software required for DP master function

No

Service as DP master

 

  • DPV0

Yes

  • DPV1

Yes

  • DPV2

Yes

Number of DP slaves operable on DP master

124

Data volume

 

  • of address area of inputs as DP master, total

30 256 bytes

  • of address area of outputs as DP master, total

30 256 bytes

  • of address area of inputs per DP slave

244 bytes

  • of address area of outputs per DP slave

244 bytes

  • of address area of diagnostics data per DP slave

244 bytes

Performance data for PROFIBUS DP slave

 

Software required for DP slave function

-

Service as DP slave

 

  • DPV0

No

  • DPV1

No

Data volume

 

  • of address area of inputs as DP slave, total

-

  • of address area of outputs as DP slave, total

-

Performance dataFMS functions

 

Software required for FMS communication

Yes, HARDNET-FMS (FMS-5613)

Number of possible connections with FMS connection, maximum

40

Performance dataS7 communication

 

Software required for S7 communication

Yes, HARDNET-S7 (S7-5613)

Number of possible connections for S7/PG communication, maximum

50

Performance dataMultiprotocol operation

 

Number of active connections in multiprotocol mode

50

Number of configurable connections per PC station

207

Product functionsManagement, configuration, programming

 

Configuration software required

NCM PC included in scope of delivery

Standards, specifications, approvals

 

Standard

 

  • For EMC

89/336/EEC

  • For CSA and UL safety

CAN/CSA C22.2 & UL 60950-1, UL 1950

  • For emitted interference

EN 50081-1, EN 50081-2

  • For noise immunity

EN 50082-1, EN 50082-2

Certificate of suitability

 

  • CE mark

Yes

  • C-Tick

Yes