Order No.

6GK1 500-3AA10

6GK1 503-2CA00

6GK1 503-3CA00

6GK1 503-2CB00

6GK1 503-3CB00

Product type designation

PROFIBUS OBT

PROFIBUS OLM P11

PROFIBUS OLM P12

PROFIBUS OLM G11

PROFIBUS OLM G12

Product description

 

 

 

 

 

Suitability for application

 

 

 

 

 

Transmission rate

 

 

 

 

 

Transmission rate

 

 

 

 

 

  • with PROFIBUS

9.6 Kbit/s … 12 Mbit/s

9.6 Kbit/s … 12 Mbit/s

9.6 Kbit/s … 12 Mbit/s

9.6 Kbit/s … 12 Mbit/s

9.6 Kbit/s … 12 Mbit/s

  • with PROFIBUS PA

45.45 Kbit/s

45.45 Kbit/s

45.45 Kbit/s

45.45 Kbit/s

45.45 Kbit/s

Interfaces

 

 

 

 

 

Maximum number of electrical/optical connections for network components or terminal equipment

3

2

3

2

3

Number of electrical connections

 

 

 

 

 

  • for network components or terminal equipment

1

1

1

1

1

  • for measuring instrument

-

1 1

1 1

1 1

1 1

  • for signaling contact

0

1

1

1

1

  • for power supply

1

0

0

0

0

  • for redundant power supply

0

1

1

1

1

Design of electrical connection

 

 

 

 

 

  • for network components or terminal equipment

9-pin sub-D socket

9-pin sub-D socket

9-pin sub-D socket

9-pin sub-D socket

9-pin sub-D socket

  • for measuring instrument

-

2-pin terminal block

2-pin terminal block

2-pin terminal block

2-pin terminal block

  • for signaling contact

 

 

 

 

 

  • for power supply

3-pin terminal block

-

-

-

-

Number of optical connections for fiber-optic cables

2

1

2

1

2

Design of optical connection for fiber-optic cables

Duplex port

BFOC port

BFOC port

BFOC port

BFOC port

Optical data

 

 

 

 

 

Attenuation factor of the FOC transmission link

 

 

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km, max.

-

-

-

-

-

  • for glass FOC with 50/125 µm at 3 dB/km, max.

-

-

-

10 dB

10 dB

  • for glass FOC with 62.5/125 µm

 

 

 

 

 

    • at 1 dB/km maximum

-

-

-

-

-

    • at 3.5 dB/km maximum

-

-

-

12 dB

12 dB

  • for PCF FOC with 200/230 µm at 10 dB/km

3 dB

-

-

-

-

  • for POF FOC with 980/1000 µm at 230 dB/km

13 dB

13 dB

13 dB

-

-

Signal delay per bit time

 

-

-

-

-

Injectable optical power relative to 1 mW

 

 

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km

-

-

-

-

-

  • for glass FOC with 50/125 µm at 3 dB/km

-

-

-

-15 dB

-15 dB

  • for glass FOC with 62.5/125 µm

 

 

 

 

 

    • at 1 dB/km

-

-

-

-

-

    • at 3.5 dB/km

-

-

-

-13 dB

-13 dB

  • of the FOC transmission link

 

 

 

 

 

    • for PCF FOC with 200/230 µm at 10 dB/km

-16 dB

-17 dB

-

-

-

    • for POF FOC with 980/1000 µm at 230 dB/km

-5.9 dB

-5 dB

-

-

-

optical sensitivity relative to 1 mW

 

 

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km

-

-

-

-

-

  • for glass FOC with 50/125 µm at 3 dB/km

-

-

-

-28 dB

-28 dB

  • for glass FOC with 62.5/125 µm

 

 

 

 

 

    • at 1 dB/km

-

-

-

-

-

    • at 3.5 dB/km

-

-

-

-28 dB

-28 dB

  • of the FOC transmission link

 

 

 

 

 

    • for PCF FOC with 200/230 µm at 10 dB/km

-22 dB

-25 dB

-

-

-

    • for POF FOC with 980/1000 µm at 230 dB/km

-20 dB

-25 dB

-

-

-

Wavelength

 

 

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm compatible with interface at 0.5 dB/km

-

-

-

-

-

  • for glass FOC with 50/125 µm compatible with interface at 3 dB/km

-

-

-

860 nm

860 nm

  • for glass FOC with 62.5/125 µm compatible with interface

 

 

 

 

 

    • at 1 dB/km

-

-

-

-

-

    • at 3.5 dB/km

-

-

-

860 nm

860 nm

  • of the FOC transmission link

 

 

 

 

 

    • for PCF FOC with 200/230 µm at 10 dB/km

660 nm

660 nm

660 nm

-

-

    • for POF FOC with 980/1000 µm at 230 dB/km

660 nm

660 nm

660 nm

-

-

Cable length

 

 

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km, max.

-

-

-

-

-

  • for glass FOC with 50/125 µm at 3 dB/km, max.

-

-

-

3 km

3 km

  • for glass FOC with 62.5/125 µm

 

 

 

 

 

    • at 1 dB/km maximum

-

-

-

-

-

    • at 3.5 dB/km maximum

-

-

-

3 km

3 km

  • for PCF FOC with 200/230 µm at 10 dB/km maximum

300 m

400 m

400 m

-

-

  • for POF FOC with 980/1000 µm at 230 dB/km, max.

50 m

80 m

80 m

-

-

Inputs/outputs

 

 

 

 

 

Nominal value of operating voltage of signal contacts with DC

-

24 V

24 V

24 V

24 V

Maximum operating current of signal contacts with DC

-

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

 

Type of power supply

DC

DC

DC

DC

DC

DC power supply

 

 

 

 

 

  • Rated value

24 V

24 V

24 V

24 V

24 V

  • Minimum

19 V

18 V

18 V

18 V

18 V

  • Maximum

28 V

32 V

32 V

32 V

32 V

Product component: fusing of power supply input

-

Yes

Yes

Yes

Yes

Type of fusing of power supply input

-

-

-

-

-

Maximum current consumed at 24 V DC

-

0.2 A

0.2 A

0.2 A

0.2 A

Effective power loss at 24 V DC

-

-

-

-

-

Permitted ambient conditions

 

 

 

 

 

Ambient temperature

 

 

 

 

 

  • During operating phase

0 … 60 °C

0 … 60 °C

0 … 60 °C

0 … 60 °C

0 … 60 °C

  • During storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • During transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

Relative humidity at 25 °C without condensation during operating phase, maximum

95 %

95 %

95 %

95 %

95 %

IP degree of protection

IP30

IP40

IP40

IP40

IP40

Design, dimensions and weights

 

 

 

 

 

Type of construction

Compact

Compact

Compact

Compact

Compact

Width

50.5 mm

39.5 mm

39.5 mm

39.5 mm

39.5 mm

Height

138 mm

110 mm

110 mm

110 mm

110 mm

Depth

78 mm

73.2 mm

73.2 mm

73.2 mm

73.2 mm

Net weight

400 g

300 g

300 g

300 g

300 g

Type of mounting

 

 

 

 

 

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

Yes

  • Wall mounting

Yes

Yes

Yes

Yes

Yes

Product properties, functions, componentsGeneral

 

 

 

 

 

Product function

 

 

 

 

 

  • Ring redundancy

No

Yes

Yes

Yes

Yes

  • Redundancy manager

 

 

 

 

 

Standards, specifications, approvals

 

 

 

 

 

Standard

 

 

 

 

 

  • for EMC of FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class  1,  Division  2,  Group  A,  B,  C,  D  /  T4,  Class  1,  Zone  2,  Group  IIC,  T4

FM3611: Class  1,  Division  2,  Group  A,  B,  C,  D  /  T4,  Class  1,  Zone  2,  Group  IIC,  T4

FM3611: Class  1,  Division  2,  Group  A,  B,  C,  D  /  T4,  Class  1,  Zone  2,  Group  IIC,  T4

FM3611: Class  1,  Division  2,  Group  A,  B,  C,  D  /  T4,  Class  1,  Zone  2,  Group  IIC,  T4

  • for Ex zone

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN  60079-0: 2006,  EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

  • for CSA and UL safety

UL  60950-1,  CSA  C22.2  No.  60950-1

UL  60950-1,  CSA  C22.2  No.  60950-1

UL  60950-1,  CSA  C22.2  No.  60950-1

UL  60950-1,  CSA  C22.2  No.  60950-1

UL  60950-1,  CSA  C22.2  No.  60950-1

  • for Ex zone of CSA and UL

-

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL  1604  and  UL  2279-15  (Hazardous  Location),  CSA  C22.2  No. 213-M1987,  Class  1  /  Division  2  /  Group  A,  B,  C,  D  /  T4,  Class  1  /  Zone  2  /  Group  IIC  /  T4

UL  1604  and  UL  2279-15  (Hazardous  Location),  CSA  C22.2  No. 213-M1987,  Class  1  /  Division  2  /  Group  A,  B,  C,  D  /  T4,  Class  1  /  Zone  2  /  Group  IIC  /  T4

UL  1604  and  UL  2279-15  (Hazardous  Location),  CSA  C22.2  No. 213-M1987,  Class  1  /  Division  2  /  Group  A,  B,  C,  D  /  T4,  Class  1  /  Zone  2  /  Group  IIC  /  T4

  • for emitted interference

EN  61000-6-4  (Class  A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • for noise immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Certificate of suitability

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

  • CE mark

Yes

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

Yes

Marine classification corporation

 

 

 

 

 

  • Bureau Veritas (BV)

No

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

No

Yes

Yes

Yes

Yes

  • Germanischer Lloyd (GL)

No

Yes

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

No

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

No

Yes

Yes

Yes

Yes


Order No.

6GK1 503-2CC00

6GK1 503-3CC00

6GK1 503-3CD00

Product type designation

PROFIBUS OLM G11-1300

PROFIBUS OLM G12-1300

PROFIBUS OLM G12 EEC

Product description

 

 

 

Suitability for application

 

 

 

Transmission rate

 

 

 

Transmission rate

 

 

 

  • with PROFIBUS

9.6 Kbit/s … 12 Mbit/s

9.6 Kbit/s … 12 Mbit/s

9.6 Kbit/s … 12 Mbit/s

  • with PROFIBUS PA

45.45 Kbit/s

45.45 Kbit/s

45.45 Kbit/s

Interfaces

 

 

 

Maximum number of electrical/optical connections for network components or terminal equipment

2

3

3

Number of electrical connections

 

 

 

  • for network components or terminal equipment

1

1

1

  • for measuring instrument

1 1

1 1

1 1

  • for signaling contact

1

1

1

  • for power supply

0

0

0

  • for redundant power supply

1

1

1

Design of electrical connection

 

 

 

  • for network components or terminal equipment

9-pin sub-D socket

9-pin sub-D socket

9-pin sub-D socket

  • for measuring instrument

2-pin terminal block

2-pin terminal block

2-pin terminal block

  • for signaling contact

 

 

 

  • for power supply

-

-

-

Number of optical connections for fiber-optic cables

1

2

2

Design of optical connection for fiber-optic cables

BFOC port

BFOC port

BFOC port

Optical data

 

 

 

Attenuation factor of the FOC transmission link

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km, max.

8 dB

8 dB

-

  • for glass FOC with 50/125 µm at 3 dB/km, max.

-

-

10 dB

  • for glass FOC with 62.5/125 µm

 

 

 

    • at 1 dB/km maximum

10 dB

10 dB

-

    • at 3.5 dB/km maximum

-

-

12 dB

  • for PCF FOC with 200/230 µm at 10 dB/km

-

-

-

  • for POF FOC with 980/1000 µm at 230 dB/km

-

-

-

Signal delay per bit time

-

-

-

Injectable optical power relative to 1 mW

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km

-19 dB

-19 dB

-

  • for glass FOC with 50/125 µm at 3 dB/km

-

-

-15 dB

  • for glass FOC with 62.5/125 µm

 

 

 

    • at 1 dB/km

-17 dB

-17 dB

-

    • at 3.5 dB/km

-

-

-13 dB

  • of the FOC transmission link

 

 

 

    • for PCF FOC with 200/230 µm at 10 dB/km

-

-

-

    • for POF FOC with 980/1000 µm at 230 dB/km

-

-

-

optical sensitivity relative to 1  mW

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km

-29 dB

-29 dB

-

  • for glass FOC with 50/125 µm at 3 dB/km

-

-

-28 dB

  • for glass FOC with 62.5/125 µm

 

 

 

    • at 1 dB/km

-29 dB

-29 dB

-

    • at 3.5 dB/km

-

-

-28 dB

  • of the FOC transmission link

 

 

 

    • for PCF FOC with 200/230 µm at 10 dB/km

-

-

-

    • for POF FOC with 980/1000 µm at 230 dB/km

-

-

-

Wavelength

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm compatible with interface at 0.5 dB/km

1 310 nm

1 310 nm

-

  • for glass FOC with 50/125 µm compatible with interface at 3 dB/km

-

-

860 nm

  • for glass FOC with 62.5/125 µm compatible with interface

 

 

 

    • at 1 dB/km

1 310 nm

1 310 nm

-

    • at 3.5 dB/km

-

-

860 nm

  • of the FOC transmission link

 

 

 

    • for PCF FOC with 200/230 µm at 10 dB/km

-

-

-

    • for POF FOC with 980/1000 µm at 230 dB/km

-

-

-

Cable length

 

 

 

  • for glass FOC with 10/125 µm or 9/125 µm at 0.5 dB/km, max.

15 km

15 km

-

  • for glass FOC with 50/125 µm at 3 dB/km, max.

-

-

3 km

  • for glass FOC with 62.5/125 µm

 

 

 

    • at 1 dB/km maximum

10 km

10 km

-

    • at 3.5 dB/km maximum

-

-

3 km

  • for PCF FOC with 200/230 µm at 10 dB/km maximum

-

-

-

  • for POF FOC with 980/1000 µm at 230 dB/km, max.

-

-

-

Inputs/outputs

 

 

 

Operating voltage of signaling contacts with DC rated value

24 V

24 V

24 V

Operating current of signaling contacts with DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

Type of power supply

DC

DC

DC

DC power supply

 

 

 

  • Rated value

24 V

24 V

24 V

  • Minimum

18 V

18 V

18 V

  • Maximum

32 V

32 V

32 V

Product component: fusing at power supply input

Yes

Yes

Yes

Type of fusing at power supply input

-

-

-

Maximum current consumed at 24 V DC

0.2 A

0.2 A

0.2 A

Effective power loss at 24 V DC

-

-

-

Permitted ambient conditions

 

 

 

Ambient temperature

 

 

 

  • During operating phase

0 … 60 °C

0 … 60 °C

-25 … +60 °C

  • During storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • During transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

Relative humidity at 25 °C without condensation during operating phase, maximum

95 %

95 %

95 %

IP degree of protection

IP40

IP40

IP40

Design, dimensions and weights

 

 

 

Type of construction

Compact

Compact

Compact

Width

39.5 mm

39.5 mm

39.5 mm

Height

110 mm

110 mm

110 mm

Depth

73.2 mm

73.2 mm

73.2 mm

Net weight

300 g

300 g

300 g

Type of mounting

 

 

 

  • 35 mm DIN rail mounting

Yes

Yes

Yes

  • Wall mounting

Yes

Yes

Yes

Product properties, functions, componentsGeneral

 

 

 

Product function

 

 

 

  • Ring redundancy

Yes

Yes

Yes

  • Redundancy manager

 

 

 

Standards, specifications, approvals

 

 

 

Standard

 

 

 

  • for EMC of FM

FM3611: Class  1,  Division  2,  Group  A,  B,  C,  D  /  T4,  Class  1,  Zone  2,  Group  IIC,  T4

FM3611: Class  1,  Division  2,  Group  A,  B,  C,  D  /  T4,  Class  1,  Zone  2,  Group  IIC,  T4

FM3611: Class  1,  Division  2,  Group  A,  B,  C,  D  /  T4,  Class  1,  Zone  2,  Group  IIC,  T4

  • for Ex zone

EN  60079-0: 2006,  EN60079-15: 2005,  II  3  G  Ex  nA  II  T4  KEMA  07  ATEX  0145X

EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0: 2006, EN60079-15: 2005, EN60079-28: 2007, II 3 (2) G Ex nA [opis] IIC T4 KEMA 09 ATEX 0173X

  • for CSA and UL safety

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for Ex zone of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL  1604  and  UL  2279-15  (Hazardous  Location),  CSA  C22.2  No. 213-M1987,  Class  1  /  Division  2  /  Group  A,  B,  C,  D  /  T4,  Class  1  /  Zone  2  /  Group  IIC  /  T4

UL  1604  and  UL  2279-15  (Hazardous  Location),  CSA  C22.2  No. 213-M1987,  Class  1  /  Division  2  /  Group  A,  B,  C,  D  /  T4,  Class  1  /  Zone  2  /  Group  IIC  /  T4

  • for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • for noise immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Certificate of suitability

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

  • CE mark

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Marine classification corporation

 

 

 

  • Bureau Veritas (BV)

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

  • Germanischer Lloyd (GL)

Yes

Yes

Yes

  • Llyods Register of Shipping (LRS)

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes