6ES7 313-6CF03-0AB0

Product version

 

associated programming package

STEP 7 V5.3 SP2 or higher with HW update

Supply voltages

 

Rated value

 

  • permissible range, lower limit (DC)

20.4 V

external protection for supply cables (recommendation)

Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A

Current consumption

 

Current consumption (rated value)

900 mA

Current consumption (in no-load operation), typ.

100 mA

Inrush current, typ.

11 A

I²t

0.7 A²·s

from supply voltage L+, max.

900 mA

Power losses

 

Power loss, typ.

10 W

Memory

 

Work memory

 

  • integrated

64 Kibyte; For program and data

  • expandable

No

Load memory

 

  • pluggable (MMC)

Yes

  • pluggable (MMC), max.

8 Mbyte

Backup

 

  • present

Yes; guaranteed by MMC (maintenance-free)

  • without battery

Yes; Program and data

CPU/ blocks

 

DB

 

  • Number, max.

511; Number range: 1 to 511

  • Size, max.

16 Kibyte

FB

 

  • Number, max.

1 024; Sequence of numbers:  0 to 2047

  • Size, max.

16 Kibyte

FC

 

  • Number, max.

1 024; Sequence of numbers:  0 to 2047

  • Size, max.

16 Kibyte

OB

 

  • Size, max.

16 Kibyte

Nesting depth

 

  • per priority class

8

  • additional within an error OB

4

CPU processing times

 

for bit operations, min.

0.1 µs

for word operations, min.

0.2 µs

for fixed point arithmetic, min.

2 µs

for floating point arithmetic, min.

3 µs

Counters, timers and their retentivity

 

S7 counter

 

  • Number

256

  • of which retentive without battery

 

    • can be set

Yes

    • lower limit

0

    • upper limit

255

  • Retentivity

 

    • can be set

Yes

    • lower limit

0

    • upper limit

255

  • Counting range

 

    • lower limit

0

    • upper limit

999

IEC counter

 

  • present

Yes

  • Type

SFB

S7 times

 

  • Number

256

  • Retentivity

 

    • can be set

Yes

    • lower limit

0

    • upper limit

255

    • preset

no retentivity

  • Time range

 

    • lower limit

10 ms

    • upper limit

9 990 s

IEC timer

 

  • present

Yes

  • Type

SFB

Data areas and their retentivity

 

Flag

 

  • Number, max.

256 byte

  • Retentivity available

Yes; MB 0 to MB 255

  • Number of clock memories

8; 1 memory byte

Data blocks

 

  • Number, max.

511; Number range: 1 to 511

  • Size, max.

16 Kibyte

  • Retentivity adjustable

Yes; via non-retain property on DB

  • Retentivity preset

yes

Local data

 

  • per priority class, max.

510 byte

Address area

 

I/O address area

 

  • overall

1 Kibyte

  • Outputs

1 Kibyte

  • of which, distributed

 

    • Inputs

1 006 byte; max.

    • Outputs

1 006 byte; max.

Process image

 

  • Inputs

128 byte

  • Outputs

128 byte

Digital channels

 

  • Inputs

8 064

  • Outputs

8 064

  • Inputs, of which central

1 008

  • Outputs, of which central

1 008

Analog channels

 

  • Inputs

503

  • Outputs

503

  • Inputs, of which central

248

  • Outputs, of which central

248

Hardware configuration

 

Central devices, max.

1

Expansion devices, max.

3

Racks, max.

4

Modules per rack, max.

8; in rack 3 max. 7

Number of DP masters

 

  • integrated

1

  • via CP

4

Number of operable FMs and CPs (recommended)

 

  • FM

8

  • CP, point-to-point

8

  • CP, LAN

6

Time of day

 

Clock

 

  • Hardware clock (real-time clock)

Yes

  • battery-backed and synchronizable

Yes

  • Deviation per day, max.

10 s

Runtime meter

 

  • Number

1

  • Number/Number range

0

  • Range of values

0 to 2^31 hours (when using SFC 101)

  • Granularity

1 hour

  • retentive

Yes

Clock synchronization

 

  • supported

Yes

  • to MPI, master

Yes

  • to MPI, slave

Yes

  • to DP, master

Yes; on DP slave only time-of-day slave

  • to DP, slave

Yes

  • in AS, master

Yes

S7 message functions

 

Number of login stations for message functions, max.

8

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

20

Test commissioning functions

 

Status/control

 

  • Status/control variable

Yes

  • Variables

Inputs, outputs, memory bits, DB, times, counters

  • Number of variables, max.

30

  • of which status variables, max.

30

  • of which control variables, max.

14

Forcing

 

  • Forcing

Yes

Status block

Yes

Single step

Yes

Number of breakpoints

2

Diagnostic buffer

 

  • present

Yes

  • Number of entries, max.

100

    • can be set

No

Communication functions

 

PG/OP communication

Yes

Routing

Yes

Global data communication

 

  • supported

Yes

  • Size of GD packets, max.

22 byte

S7 basic communication

 

  • supported

Yes

S7 communication

 

  • supported

Yes

S5-compatible communication

 

  • supported

Yes; via CP and loadable FC

Number of connections

 

  • overall

8

  • usable for PG communication

7

  • usable for OP communication

7

  • usable for S7 basic communication

4

  • usable for routing

4; max.

Connection method

 

required front connector

1x 40-pin

MPI

 

Cable length, max.

50 m; without repeater

1st interface

 

Type of interface

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Functionality

 

  • MPI

Yes

  • DP master

No

  • DP slave

No

  • Point-to-point connection

No

MPI

 

  • Number of connections

8

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

Yes

    • S7 basic communication

Yes

    • S7 communication

Yes

    • S7 communication, as client

No

    • S7 communication, as server

Yes

  • Transmission rate, max.

187.5 kbit/s

2nd interface

 

Type of interface

integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Number of connection resources

8

Functionality

 

  • MPI

No

  • DP master

Yes

  • DP slave

Yes

  • PROFINET IO Controller

No

  • PROFINET CBA

No

  • Point-to-point connection

No

DP master

 

  • Number of connections, max.

8; for PG / OP communication

  • Number of connections (of which reserved), max.

1 for PG, 1 for OP

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

No

    • S7 basic communication

Yes; I blocks only

    • S7 communication

Yes

    • S7 communication, as client

No

    • S7 communication, as server

Yes

    • Equidistance mode support

Yes

    • Isochronous mode

No

    • SYNC/FREEZE

Yes

    • Activation/deactivation of DP slaves

Yes

    • Direct data exchange (slave-to-slave communication)

Yes

    • DPV1

Yes

  • Transmission speeds, max.

12 Mbit/s

  • Number of DP slaves, max.

32

  • Address area

 

    • Inputs, max.

1 Kibyte

    • Outputs, max.

1 Kibyte

  • User data per DP slave

 

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

DP slave

 

  • Number of connections

8

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes; Only with active interface

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication, as client

No

    • S7 communication, as server

Yes

    • Direct data exchange (slave-to-slave communication)

Yes

    • DPV1

No

  • GSD file

The current GSD file can be obtained from: http://www.siemens.de/profibus-gsd

  • Transmission rate, max.

12 Mbit/s

  • Automatic baud rate search

Yes; only with passive interface

  • Transfer memory

 

    • Inputs

244 byte

    • Outputs

244 byte

  • Address area, max.

32

  • User data per address area, max.

32 byte

CPU/ programming

 

Programming language

 

  • STEP 7

Yes; V5.3 SP2 with HW update

  • LAD

Yes

  • FBD

Yes

  • STL

Yes

  • SCL

Yes

  • GRAPH

Yes

  • HiGraph®

Yes

Command set

see instruction list

Nesting levels

8

Know-how protection

 

  • User program protection/password protection

Yes

System functions (SFC)

see instruction list

System function blocks (SFB)

see instruction list

Digital inputs

 

Number of digital inputs

16

  • of which, inputs usable for technological functions

12

Number of simultaneously controllable inputs

 

  • horizontal installation

 

    • up to 40 °C, max.

16

    • up to 60 °C, max.

8

  • vertical installation

 

    • up to 40 °C, max.

8

  • Technological functions

 

    • shielded, max.

100 m

    • unshielded, max.

not allowed

  • Standard DI

 

    • shielded, max.

1 000 m

    • unshielded, max.

600 m

Input characteristic curve acc. to IEC 1131, Type 1

Yes

Input voltage

 

  • Rated value, DC

24 V

  • for signal "0"

-3 to +5 V

  • for signal "1"

15 to 30 V

Input current

 

  • for signal "1", typ.

9 mA

Input delay (for rated value of input voltage)

 

  • for standard inputs

 

    • parameterizable

Yes; 0.1 / 0.3 / 3 / 15 ms

    • Rated value

3 ms

  • for counter/technological functions

 

    • at "0" to "1", max.

16 µs

Cable length

 

  • Cable length, shielded, max.

1 000 m; 100 m for technological functions

  • Cable length unshielded, max.

600 m; For technological functions: No

Digital outputs

 

Number of digital outputs

16

  • of which high-speed outputs

4

Short-circuit protection

Yes; Clocked electronically

  • Response threshold, typ.

1 A

Limitation of inductive shutdown voltage to

L+ (-48 V)

Lamp load, max.

5 W

Controlling a digital input

Yes

Output voltage

 

  • for signal "1", min.

L+ (-0.8 V)

Output current

 

  • for signal "1" rated value

500 mA

  • for signal "1" permissible range, min.

5 mA

  • for signal "1" permissible range, max.

0.6 A

  • for signal "1" minimum load current

5 mA

  • for signal "0" residual current, max.

0.5 mA

Parallel switching of 2 outputs

 

  • for increased power

No

  • for redundant control of a load

Yes

Switching frequency

 

  • with resistive load, max.

100 Hz

  • with inductive load, max.

0.5 Hz

  • on lamp load, max.

100 Hz

  • of the pulse outputs, with resistive load, max.

2.5 kHz

Aggregate current of outputs (per group)

 

  • horizontal installation

 

    • up to 40 °C, max.

3 A

    • up to 60 °C, max.

2 A

  • vertical installation

 

    • up to 40 °C, max.

2 A

Load resistance range

 

  • lower limit

48 Ω

  • upper limit

4 kΩ

Cable length

 

  • Cable length, shielded, max.

1 000 m

  • Cable length unshielded, max.

600 m

Encoder

 

Connectable encoders

 

  • 2-wire BEROS

Yes

    • permissible quiescent current (2-wire BEROS), max.

1.5 mA

Integrated Functions

 

Number of counters

3; 3 channels (see "Technological Functions" manual)

Counter frequency (counter) max.

30 kHz

Frequency measurement

Yes

controlled positioning

No

PID controller

Yes

Number of pulse outputs

3; 3 channels pulse width modulation up to max. 2.5 kHz (see "Technological Functions" manual)

Limit frequency (pulse)

2.5 kHz

Galvanic isolation

 

Galvanic isolation digital inputs

 

  • Galvanic isolation digital inputs

Yes

  • between the channels

No

  • between the channels and the backplane bus

Yes

Galvanic isolation digital outputs

 

  • Galvanic isolation digital outputs

Yes

  • between the channels

Yes

  • between the channels, in groups of

8

  • between the channels and the backplane bus

Yes

Dimensions and weight

 

Dimensions

 

  • Width

120 mm

  • Height

125 mm

  • Depth

130 mm

Weight

 

  • Weight, approx.

566 g