6ES7 334-0CE01-0AA0 |
6ES7 334-0KE00-0AB0 |
Supply voltages |
|
|
Load voltage L+ |
|
|
|
24 V |
24 V |
Current consumption |
|
|
from load voltage L+ (without load), max. |
110 mA |
80 mA |
from backplane bus 5 V DC, max. |
55 mA |
60 mA |
Power losses |
|
|
Power loss, typ. |
3 W |
2 W |
Connection method |
|
|
required front connector |
20-pin |
20-pin |
Analog inputs |
|
|
Number of analog inputs |
4 |
4 |
Number of analog inputs for voltage measurement |
4 |
2 |
Number of analog inputs for resistance measurement |
|
4 |
Cycle time (all channels) max. |
5 ms |
85 ms |
Input ranges (rated values), voltages |
|
|
|
Yes |
Yes |
Input ranges (rated values), currents |
|
|
|
Yes |
|
Input ranges (rated values), resistance thermometers |
|
|
|
|
Yes; only climatic range |
Input ranges (rated values), resistors |
|
|
|
|
Yes |
Voltage input |
|
|
|
20 V |
20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) |
Current input |
|
|
|
40 mA |
|
Analog outputs |
|
|
Number of analog outputs |
2 |
2 |
Cable length, shielded, max. |
200 m |
100 m |
Voltage output, short-circuit protection |
Yes |
Yes |
Voltage output, short-circuit current, max. |
11 mA |
10 mA |
Current output, no-load voltage, max. |
15 V |
|
Output ranges, voltage |
|
|
|
Yes |
Yes |
Output ranges, current |
|
|
|
Yes |
|
Load impedance (in rated range of output) |
|
|
|
5 kΩ |
2.5 kΩ |
|
1 µF |
1 µF |
|
300 Ω |
|
|
1 mH |
|
Analog value creation |
|
|
Integrations and conversion time/ resolution per channel |
|
|
|
8 bit |
12 bit |
|
|
16.67/20 ms |
Settling time |
|
|
|
0.3 ms |
0.8 ms |
|
3 ms |
0.8 ms |
|
0.3 ms |
|
Encoder |
|
|
Connection of signal encoders |
|
|
|
Yes |
|
|
|
Yes |
|
|
Yes |
|
|
Yes |
Errors/accuracies |
|
|
Operational limit in overall temperature range |
|
|
|
+/- 0,9 % |
+/- 0,7 %; 0 to 10 V |
|
+/- 0,8 % |
|
|
|
+/- 3,5 %; 10 kOhm |
|
|
+/- 1 % |
|
+/- 0,6 % |
+/- 1 % |
|
+/- 1 % |
|
Basic error limit (operational limit at 25 °C) |
|
|
|
+/- 0,7 % |
+/- 0,5 %; 0 to 10 V |
|
+/- 0,6 % |
|
|
|
+/- 2,8 %; 10 kOhm |
|
|
+/- 0,8 % |
|
+/- 0,5 % |
+/- 0,85 % |
|
+/- 0,5 % |
|
Interrupts/diagnostics/status information |
|
|
Alarms |
|
|
|
No |
No |
Diagnoses |
|
|
|
No |
No |
Isolation |
|
|
Isolation checked with |
500 VDC |
500 VDC |
Galvanic isolation |
|
|
Galvanic isolation analog inputs |
|
|
|
No |
Yes |
Galvanic isolation analog outputs |
|
|
|
No |
Yes |
Dimensions and weight |
|
|
Dimensions |
|
|
|
40 mm |
40 mm |
|
125 mm |
125 mm |
|
120 mm |
120 mm |
Weight |
|
|
|
285 g |
200 g |