6ES7 417-4HT14-0AB0

Product version

 

Hardware product version

1

Firmware version

V4.5

associated programming package

STEP7 V 5.3 SP2 or higher with HW update

Supply voltages

 

Rated value

 

  • 24 V DC

No; Power supply via system power supply

Feeding of external backup voltage to CPU

5 to 15 VDC

Current consumption

 

from backplane bus 5 V DC, max.

1.8 A

from interface 5 V DC, max.

90 mA; At each DP interface

Power losses

 

Power loss, typ.

6.5 W

Backup battery

 

Battery operation

 

  • Backup current, typ.

970 µA; Valid up to 40°C

  • Backup current, max.

1 980 µA

Memory

 

Work memory

 

  • integrated (for program)

15 Mbyte

  • integrated (for data)

15 Mbyte

  • expandable

No

Load memory

 

  • expandable FEPROM

Yes

  • expandable FEPROM, max.

64 Mbyte

  • integrated RAM, max.

256 Kibyte

  • expandable RAM

Yes

  • expandable RAM, max.

64 Mbyte

Backup

 

  • present

Yes

  • with battery

Yes; All data

  • without battery

No

CPU/ blocks

 

DB

 

  • Number, max.

8 191; Number range: 1 - 8191

  • Size, max.

64 Kibyte

FB

 

  • Number, max.

6 144; Number range: 0 - 6143

  • Size, max.

64 Kibyte

FC

 

  • Number, max.

6 144; Number range: 0 - 6143

  • Size, max.

64 Kibyte

OB

 

  • Size, max.

64 Kibyte

Nesting depth

 

  • per priority class

24

  • additional within an error OB

2

CPU processing times

 

for bit operations, min.

0.018 µs

for word operations, min.

0.018 µs

for fixed point arithmetic, min.

0.018 µs

for floating point arithmetic, min.

0.054 µs

Counters, timers and their retentivity

 

S7 counter

 

  • Number

2 048

  • Retentivity

 

    • can be set

Yes

    • lower limit

0

    • upper limit

2 047

    • preset

Z 0 to Z 7

  • Counting range

 

    • lower limit

0

    • upper limit

999

IEC counter

 

  • present

Yes

  • Type

SFB

S7 times

 

  • Number

2 048

  • Retentivity

 

    • can be set

Yes

    • lower limit

0

    • upper limit

2 047

    • preset

No times retentive

  • Time range

 

    • lower limit

10 ms

    • upper limit

9 990 s

IEC timer

 

  • present

Yes

  • Type

SFB

Data areas and their retentivity

 

retentive data area, total

Total working and load memory (with backup battery)

Flag

 

  • Number, max.

16 Kibyte

  • Retentivity available

Yes

  • Number of clock memories

8; (in 1 memory byte)

Data blocks

 

  • Number, max.

8 191; Number range: 1 - 8191

  • Size, max.

64 Kibyte

Local data

 

  • adjustable, max.

64 Kibyte

  • preset

32 Kibyte

Address area

 

I/O address area

 

  • overall

16 Kibyte

  • Outputs

16 Kibyte

  • of which, distributed

 

    • MPI/DP interface, inputs

2 Kibyte

    • MPI/DP interface, outputs

2 Kibyte

    • DP interface, inputs

8 Kibyte

    • DP interface, outputs

8 Kibyte

Process image

 

  • Inputs, adjustable

16 Kibyte

  • Outputs, adjustable

16 Kibyte

  • Inputs, default

1 024 byte

  • Outputs, default

1 024 byte

  • consistent data, max.

244 byte

  • Access to consistent data in process image

Yes

Subprocess images

 

  • Number of subprocess images, max.

15

Digital channels

 

  • Inputs

131 072

  • Outputs

131 072

  • Inputs, of which central

131 072

  • Outputs, of which central

131 072

Analog channels

 

  • Inputs

8 192

  • Outputs

8 192

  • Inputs, of which central

8 192

  • Outputs, of which central

8 192

Hardware configuration

 

connectable OPs

63 without message processing, 16 with message processing

Central devices, max.

1

Expansion devices, max.

21

Multicomputing

No

Interface modules

 

  • Number of connectable IMs (total), max.

6

  • Number of connectable IM 460s, max.

6

  • Number of connectable IM 463s, max.

4; Single mode only

Number of DP masters

 

  • integrated

2

  • via CP

10

  • Mixed mode IM + CP permitted

No

Number of operable FMs and CPs (recommended)

 

  • FM

See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections

  • CP, point-to-point

See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections

  • PROFIBUS and Ethernet CPs

14; Of which max. 10 CP as DP master

Time of day

 

Clock

 

  • Hardware clock (real-time clock)

Yes

  • battery-backed and synchronizable

Yes

  • Resolution

1 ms

Runtime meter

 

  • Number

8

Clock synchronization

 

  • supported

Yes

  • to MPI, master

Yes

  • to MPI, slave

Yes

  • to DP, master

Yes

  • to DP, slave

Yes

  • in AS, master

Yes

  • in AS, slave

Yes

S7 message functions

 

Number of login stations for message functions, max.

16

Symbol-related messages

No

Block related messages

Yes

Alarm 8-blocks

Yes

Process control messages

Yes

Test commissioning functions

 

Status/control

 

  • Status/control variable

Yes

Forcing

 

  • Forcing

Yes

Status block

Yes

Single step

Yes

Number of breakpoints

4

Diagnostic buffer

 

  • present

Yes

  • Number of entries, max.

3 200

    • can be set

Yes

    • preset

120

Communication functions

 

PG/OP communication

Yes

Routing

Yes

Global data communication

 

  • supported

No

S7 basic communication

 

  • supported

No

S7 communication

 

  • supported

Yes

  • as server

Yes

  • as client

Yes

  • User data per job, max.

64 Kibyte

S5-compatible communication

 

  • supported

Yes; (via CP max. 10 and FC AG_SEND and FC AG_RECV)

  • User data per job, max.

8 Kibyte

Standard communication (FMS)

 

  • supported

Yes; Via CP and loadable FB

Number of connections

 

  • overall

64

1st interface

 

Type of interface

Integrated

Physics

RS 485 / PROFIBUS + MPI

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150 mA

Number of connection resources

MPI: 44, DP: 32

Functionality

 

  • MPI

Yes

  • DP master

Yes

  • DP slave

No

MPI

 

  • Number of connections

44

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes

    • S7 communication, as client

Yes

    • S7 communication, as server

Yes

  • Transmission rate, max.

12 Mbit/s

DP master

 

  • Number of connections, max.

32

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes

    • S7 communication, as client

Yes

    • S7 communication, as server

Yes

    • Equidistance mode support

No

    • SYNC/FREEZE

No

    • Activation/deactivation of DP slaves

No

    • Direct data exchange (slave-to-slave communication)

No

  • Transmission rate, max.

12 Mbit/s

  • Number of DP slaves, max.

32

  • Address area

 

    • Inputs, max.

2 Kibyte

    • Outputs, max.

2 Kibyte

  • User data per DP slave

 

    • User data per DP slave, max.

244 byte

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

    • Slots, max.

244

    • per slot, max.

128 byte

2nd interface

 

Type of interface

Integrated

Physics

RS 485 / PROFIBUS + MPI

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150 mA

Number of connection resources

32

Functionality

 

  • DP master

Yes

  • DP slave

No

DP master

 

  • Number of connections, max.

32

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes

    • Equidistance mode support

No

    • SYNC/FREEZE

No

    • Direct data exchange (slave-to-slave communication)

No

  • Transmission speeds, max.

12 Mbit/s

  • Number of DP slaves, max.

125

  • Address area

 

    • Inputs, max.

8 Kibyte

    • Outputs, max.

8 Kibyte

  • User data per DP slave

 

    • User data per DP slave, max.

244 byte

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

    • Slots, max.

244

    • per slot, max.

128 byte

3rd interface

 

Type of interface

Pluggable synchronization submodule (FO)

Plug-in interface modules

Synchronization submodule IF 960 6ES7 960-1AA04-0XA0 or 6ES7 960-1AB04-0XA0

4th interface

 

Type of interface

Pluggable synchronization submodule (FO)

Plug-in interface modules

Synchronization submodule IF 960 6ES7 960-1AA04-0XA0 or 6ES7 960-1AB04-0XA0

CiR - Configuration in RUN

 

CiR synchronization time, basic load

60 ms

CiR synchronization time, time per I/O slave

10 µs

CPU/ programming

 

Configuration software

 

  • STEP 7

Yes; With hardware update as of STEP7 V5.3 SP2

Programming language

 

  • STEP 7

Yes

  • LAD

Yes

  • FBD

Yes

  • STL

Yes

  • SCL

Yes

  • CFC

Yes

  • GRAPH

Yes

  • HiGraph®

Yes

Nesting levels

8

Know-how protection

 

  • User program protection/password protection

Yes

Dimensions

 

Required slots

2

Dimensions and weight

 

Dimensions

 

  • Width

50 mm

  • Height

290 mm

  • Depth

219 mm

Weight

 

  • Weight, approx.

995 g