6ED1 055-1CB00-0BA0 |
6ED1 055-1HB00-0BA0 |
6ED1 055-1MB00-0BA1 |
6ED1 055-1FB00-0BA1 |
Supply voltages |
|
|
|
|
Rated value |
|
|
|
|
|
|
|
Yes |
|
|
Yes |
Yes |
Yes |
|
|
|
|
|
Yes |
|
|
|
|
Yes |
|
20.4 V |
20.4 V |
10.8 V |
100 V |
|
28.8 V |
28.8 V |
28.8 V |
253 V |
|
|
Yes |
|
|
|
|
|
|
Yes |
|
|
|
|
Yes |
|
|
20.4 V |
|
85 V |
|
|
26.4 V |
|
265 V |
Digital inputs |
|
|
|
|
Number of digital inputs |
4 |
4 |
4 |
4 |
Digital outputs |
|
|
|
|
Number of digital outputs |
4 |
4; Relay |
4; Relay |
4; Relay |
Short-circuit protection |
Yes; electrical (1 A) |
No; external fusing necessary |
No; external fusing necessary |
No; external fusing necessary |
Relay outputs |
|
|
|
|
Switching capacity of contacts |
|
|
|
|
|
|
3 A |
3 A |
3 A |
|
|
5 A |
5 A |
5 A |
|
0.3 A |
|
|
|
EMC |
|
|
|
|
|
Yes |
Yes |
Yes |
Yes |
Environmental requirements |
|
|
|
|
Operating temperature |
|
|
|
|
|
0 °C |
0 °C |
0 °C |
0 °C |
|
55 °C |
55 °C |
55 °C |
55 °C |
Degree of protection |
|
|
|
|
IP20 |
Yes |
Yes |
Yes |
Yes |
Standards, approvals, certificates |
|
|
|
|
CSA approval |
Yes |
Yes |
Yes |
Yes |
developed according to IEC1131-3 |
Yes |
Yes |
Yes |
Yes |
FM approval |
Yes |
Yes |
Yes |
Yes |
according to VDE 0631 |
Yes |
Yes |
Yes |
Yes |
Marine approval |
Yes |
Yes |
Yes |
Yes |
UL approval |
Yes |
Yes |
Yes |
Yes |
Dimensions and weight |
|
|
|
|
Dimensions |
|
|
|
|
|
on 35 mm DIN rail, 2 spacing units wide |
on 35 mm DIN rail, 2 spacing units wide |
on 35 mm DIN rail, 2 spacing units wide |
on 35 mm DIN rail, 2 spacing units wide |
|
36 mm; 2 DU |
36 mm; 2 DU |
36 mm; 2 DU |
36 mm; 2 DU |
|
90 mm |
90 mm |
90 mm |
90 mm |
|
55 mm |
55 mm |
55 mm |
55 mm |
|
6ED1 055-1CB10-0BA0 |
6ED1 055-1NB10-0BA0 |
6ED1 055-1FB10-0BA0 |
Supply voltages |
|
|
|
Rated value |
|
|
|
|
Yes |
Yes |
|
|
|
|
Yes |
|
|
|
Yes |
|
20.4 V |
20.4 V |
100 V |
|
28.8 V |
28.8 V |
253 V |
|
|
|
Yes |
|
|
|
Yes |
|
|
|
85 V |
|
|
|
265 V |
|
|
|
47 Hz |
|
|
|
63 Hz |
Digital inputs |
|
|
|
Number of digital inputs |
8 |
8 |
8 |
Input voltage |
|
|
|
|
< 5 V DC |
< 5 V DC |
< 40 V AC; < 30 V DC |
|
> 12 V DC |
> 12 V DC |
> 79 V AC; > 79 V DC |
Input current |
|
|
|
|
1 mA |
1 mA |
0.03 mA |
|
2 mA |
2 mA |
0.08 mA |
Input delay (for rated value of input voltage) |
|
|
|
|
|
|
|
|
1.5 ms |
1.5 ms |
50 ms |
|
1.5 ms |
1.5 ms |
50 ms |
Digital outputs |
|
|
|
Number of digital outputs |
8 |
8; Relay |
8; Relay |
Short-circuit protection |
Yes; electrical (1 A) |
No; external fusing necessary |
external fusing necessary |
Lamp load, max. |
|
1 000 W; 500 W at 115 V AC |
1 000 W; 500 W at 115 V AC |
Controlling a digital input |
Yes |
Yes |
Yes |
Parallel switching of 2 outputs |
|
|
|
|
No |
No |
No |
Switching frequency |
|
|
|
|
10 Hz |
2 Hz |
2 Hz |
|
0.5 Hz |
0.5 Hz |
0.5 Hz |
|
|
10 Hz |
10 Hz |
Relay outputs |
|
|
|
Switching capacity of contacts |
|
|
|
|
|
3 A |
3 A |
|
|
5 A |
5 A |
|
0.3 A |
|
|
EMC |
|
|
|
|
Yes |
Yes |
Yes |
Environmental requirements |
|
|
|
Operating temperature |
|
|
|
|
0 °C |
0 °C |
0 °C |
|
55 °C |
55 °C |
55 °C |
Degree of protection |
|
|
|
IP20 |
Yes |
Yes |
Yes |
Standards, approvals, certificates |
|
|
|
CSA approval |
Yes |
Yes |
Yes |
developed according to IEC1131-3 |
Yes |
Yes |
Yes |
FM approval |
Yes |
Yes |
Yes |
according to VDE 0631 |
Yes |
Yes |
Yes |
Marine approval |
Yes |
Yes |
Yes |
UL approval |
Yes |
Yes |
Yes |
Dimensions and weight |
|
|
|
Dimensions |
|
|
|
|
on 35 mm DIN rail, 4 spacing units wide |
on 35 mm DIN rail, 4 spacing units wide |
on DIN rail 25 mm, 4 module spaces wide |
|
72 mm; 4 DU |
72 mm; 4 DU |
72 mm; 4 DU |
|
90 mm |
90 mm |
90 mm |
|
53 mm |
53 mm |
53 mm |
|
6ED1 055-1MA00-0BA0 |
6ED1 055-1MD00-0BA1 |
Product type designation |
|
LOGO! AM2 RTD |
Supply voltages |
|
|
Rated value |
|
|
|
Yes |
Yes; 10,8 ... 28.8 V DC |
|
Yes |
Yes |
Analog inputs |
|
|
Number of analog inputs |
2 |
2; 2 or 3 wire connection |
Input ranges |
|
|
|
Yes |
|
|
Yes |
|
|
|
Yes; for PT100/PT1000 sensors |
Input ranges (rated values), voltages |
|
|
|
Yes |
|
Input ranges (rated values), currents |
|
|
|
Yes |
|
EMC |
|
|
Emission of radio interference acc. to EN 55 011 |
|
|
|
Yes |
Yes |
Environmental requirements |
|
|
Operating temperature |
|
|
|
0 °C |
0 °C |
|
55 °C |
55 °C |
Degree of protection |
|
|
IP20 |
Yes |
Yes |
Standards, approvals, certificates |
|
|
CSA approval |
Yes |
Yes; C22.2 Number 142 |
developed according to IEC1131-3 |
Yes |
Yes; EN 61131-2 (IEC 1131-2) |
FM approval |
Yes |
Yes; FM-Standards No. 3611, 3600, 3810 Class I, Division 2, Group A, B, C, D |
according to VDE 0631 |
Yes |
|
Marine approval |
Yes |
Yes; ABS, BV, DNV, GL, LRS, Class NK |
UL approval |
Yes |
Yes |
Dimensions and weight |
|
|
Dimensions |
|
|
|
on 35 mm DIN rail, 2 spacing units wide |
|
|
36 mm |
36 mm |
|
90 mm |
90 mm |
|
55 mm |
53 mm |
|
6ED1 055-1MM00-0BA1 |
Supply voltages |
|
Rated value |
|
|
No |
|
Yes |
Analog outputs |
|
Number of analog outputs |
2 |
Output ranges, voltage |
|
|
Yes |
EMC |
|
Emission of radio interference acc. to EN 55 011 |
|
|
Yes |
Environmental requirements |
|
Operating temperature |
|
|
0 °C |
|
55 °C |
Degree of protection |
|
IP20 |
Yes |
Standards, approvals, certificates |
|
CSA approval |
Yes |
developed according to IEC1131-3 |
Yes |
FM approval |
Yes |
according to VDE 0631 |
Yes |
Marine approval |
Yes |
UL approval |
Yes |
Dimensions and weight |
|
Dimensions |
|
|
on 35 mm DIN rail, 2 spacing units wide |
|
36 mm |
|
90 mm |
|