6ES7 153-2BA02-0XB0

Power supply

 

Input current

 

  • Rated value at 24 V DC

650 mA

Output voltage

 

  • Rated value, 5 V DC

Yes

Output current

 

  • for backplane bus (5 V DC), max.

1.5 A

Supply voltages

 

Rated value

 

  • 24 V DC

Yes

  • permissible range (ripple included), lower limit (DC)

20.4 V

  • permissible range (ripple included), upper limit (DC)

28.8 V

external protection for supply cables (recommendation)

2.5 A

Mains buffering

 

  • Mains/voltage failure stored energy time

5 ms

Current consumption

 

Current consumption, max.

600 mA

Inrush current, typ.

3 A

I²t

0.1 A²·s

Power losses

 

Power loss, typ.

5.5 W

Address area

 

Addressing volume

 

  • Outputs

244 byte

  • Inputs

244 byte

Hardware configuration

 

Number of modules per DP slave interface, max.

12

Communication functions

 

Bus protocol/transmission protocol

PROFIBUS DP to EN 50170

Interfaces

 

PROFIBUS DP, output current, max.

70 mA

Interface physics, RS 485

Yes

Interface physics, FOC

No

Connection method

 

PROFIBUS DP

9-pin sub D

PROFIBUS DP

 

Transmission procedure

RS 485

Transmission rate, max.

12 Mbit/s

Node addresses

1 to 125 permitted

Automatic detection of transmission speed

Yes

SYNC capability

Yes

FREECE capability

Yes

Direct data exchange (slave-to-slave communication)

Yes; Sender

1st interface

 

DP slave

 

  • GSD file

SI04801.GSG

  • Automatic baud rate search

Yes

CPU/ programming

 

Configuration software

 

  • STEP 7

Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file

Time stamping

 

Accuracy

1 ms; 1ms at up to 8 modules; 10ms at up to 12 modules

Number of message buffers

15

Messages per message buffer

20

Number of stampable digital inputs, max.

128; Max. 128 signals/station; max. 32 signals/slot

Time format

RFC 1119

Time resolution

0.466 ns

Time interval for transmitting the message buffer if a message is present

1 000 ms

Time stamp on signal change

rising / falling edge as signal entering or exiting

Isolation

 

Isolation checked with

Isolation voltage 500 V

Environmental requirements

 

Operating temperature

 

  • Min.

0 °C

  • max.

60 °C

Air pressure

 

  • Operating altitude above sea level, max.

3 000 m

Degree of protection

 

IP20

Yes

General information

 

Vendor identification (VendorID)

801Eh

Dimensions and weight

 

Dimensions

 

  • Width

40 mm

  • Height

125 mm

  • Depth

117 mm

Weight

 

  • Weight, approx.

360 g


 

6ES7 197-1LB00-0XA0

System

 

Requirements for DP master system

 

  • Length of parameter assignment message

244 byte

Supply voltages

 

Description

via bus module

Rated value

 

  • permissible range, lower limit (DC)

20.4 V

  • permissible range, upper limit (DC)

28.8 V

Protocols

 

PROFIBUS DP protocol

Yes

PROFIBUS DP

 

Properties of the lower-level DP master systems

 

  • Transmission rate, max.

12 Mbit/s; 45.45 Kbit/s to 12 Mbit/s

  • Termination of lower-level DP master system

Active terminating resistor (Bus Terminator)

  • Use of OLM/OBT

Yes

  • Use of RS 485 repeaters, max.

9

  • Number of DP slaves, max.

31; 64 when using RS 485 repeaters or OLM/OBT

Interrupts/diagnostics/status information

 

Status indicator

No

Alarms

 

  • Alarms

No

Diagnoses

 

  • Diagnostic functions

Yes

Galvanic isolation

 

to lower-level DP master system

Yes

Dimensions and weight

 

Dimensions

 

  • Width

40 mm

  • Height

125 mm

  • Depth

130 mm

Weight

 

  • Weight, approx.

200 g