6ES7 151-7AB00-0AB0

6ES7 151-7AA20-0AB0

Product version

 

 

associated programming package

 

STEP 7 V5.2 + SP1 or higher with HW update

Supply voltages

 

 

Rated value

 

 

  • permissible range, lower limit (DC)

20.4 V

 

Load voltage L+

 

 

  • Rated value (DC)

 

24 V

  • permissible range, lower limit (DC)

 

20.4 V

  • permissible range, upper limit (DC)

 

28.8 V

  • Short-circuit protection

 

Yes

  • Reverse polarity protection

 

Yes

Current consumption

 

 

Inrush current, max.

3.5 A

 

Current output to backplane bus (DC 5 V), max.

 

700 mA

from supply voltage 1L+, max.

 

250 mA; 280 mA with DP master module

Power losses

 

 

Power loss, typ.

 

3.3 W

Memory

 

 

Work memory

 

 

  • integrated

48 Kibyte; as of FW V1.13 48 KB; previously 24 KB

96 Kibyte; For program and data

  • expandable

 

No

Load memory

 

 

  • pluggable (MMC)

 

Yes

  • pluggable (MMC), max.

 

8 Mbyte

CPU/ blocks

 

 

Number of blocks (total)

 

1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

 

 

  • Number, max.

127

511; Number range: 1 to 511

  • Size, max.

 

16 Kibyte

FB

 

 

  • Number, max.

128

1 024; Number range: 0 to 2047

  • Size, max.

 

16 Kibyte

FC

 

 

  • Number, max.

128

1 024; Number range: 0 to 2047

  • Size, max.

 

16 Kibyte

OB

 

 

  • Size, max.

 

16 Kibyte

Nesting depth

 

 

  • per priority class

8

8

  • additional within an error OB

 

4

CPU processing times

 

 

for bit operations, min.

0.1 µs

0.1 µs

for word operations, min.

1 µs

0.2 µs

for fixed point arithmetic, min.

2 µs

2 µs

for floating point arithmetic, min.

20 µs

3 µs

Counters, timers and their retentivity

 

 

S7 counter

 

 

  • Number

256

256

  • Retentivity

 

 

    • can be set

 

Yes

    • lower limit

 

0

    • upper limit

 

255

    • preset

 

Z 0 to Z 7

  • Counting range

 

 

    • can be set

Yes

Yes

    • lower limit

1

0

    • upper limit

999

999

IEC counter

 

 

  • Type

 

SFB

  • Number

 

Unlimited (limited only by RAM capacity)

S7 times

 

 

  • Number

256

256

  • Retentivity

 

 

    • can be set

 

Yes

    • lower limit

 

0

    • upper limit

 

255

    • preset

 

No retentivity

  • Time range

 

 

    • lower limit

10 ms

10 ms

    • upper limit

9 990 s

9 990 s

IEC timer

 

 

  • Type

 

SFB

  • Number

 

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

 

 

retentive data area in total (incl. times, counters, flags), max.

4 Kibyte

64 Kibyte

Flag

 

 

  • Number, max.

256 byte

256 byte

  • Retentivity available

 

Yes

  • Retentivity preset

 

MB 0 to MB 15

  • Number of clock memories

 

8; 1 memory byte

Data blocks

 

 

  • Number, max.

 

511; Number range: 1 to 511

  • Size, max.

 

16 Kibyte

Local data

 

 

  • per priority class, max.

 

510 byte

Address area

 

 

I/O address area

 

 

  • overall

 

2 048 byte

  • Outputs

 

2 048 byte

Process image

 

 

  • Inputs

 

128 byte; Not adjustable

  • Outputs

 

128 byte; Not adjustable

Digital channels

 

 

  • Inputs

 

16 336

  • Outputs

 

16 336

  • Inputs, of which central

 

248

  • Outputs, of which central

 

248

Analog channels

 

 

  • Inputs

 

1 021

  • Outputs

 

1 021

  • Inputs, of which central

 

124

  • Outputs, of which central

 

124

Addressing volume

 

 

  • Outputs

244 byte

 

  • Inputs

244 byte

 

Hardware configuration

 

 

Number of modules per system, max.

63

63; Centralized

Connectable programming devices/PCs

PGs/OPs with STEP 7 connectable via PROFIBUS interface

 

Time of day

 

 

Clock

 

 

  • Hardware clock (real-time clock)

 

Yes

  • battery-backed and synchronizable

 

Yes

  • Backup time

 

6 wk; At 40 °C ambient temperature, typically

  • Deviation per day, max.

 

10 s

Runtime meter

 

 

  • Number

 

1

  • Number/Number range

 

0

  • Range of values

 

0 to 2^31 hours (when using SFC 101)

  • Granularity

 

1 hour

  • retentive

 

Yes; Must be restarted at each restart

Clock synchronization

 

 

  • supported

 

Yes

  • to MPI, master

 

Yes

  • to MPI, slave

 

Yes

  • to DP, master

 

Yes

  • to DP, slave

 

Yes

  • in AS, master

 

No

  • in AS, slave

 

No

S7 message functions

 

 

Number of login stations for message functions, max.

 

12; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

 

Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ

simultaneously active Alarm-S blocks, max.

 

40

Test commissioning functions

 

 

Status/control

 

 

  • Status/control variable

 

Yes

  • Variables

 

Inputs, outputs, memory bits, DB, times, counters

  • Number of variables, max.

 

30

  • of which status variables, max.

 

30

  • of which control variables, max.

 

14

Forcing

 

 

  • Forcing

 

Yes

Status block

 

Yes

Single step

 

Yes

Number of breakpoints

 

2

Diagnostic buffer

 

 

  • present

Yes

Yes

  • Number of entries, max.

100

100

    • can be set

 

No

Communication functions

 

 

PG/OP communication

 

Yes

Global data communication

 

 

  • supported

 

Yes

  • Number of GD packets, max.

 

4

  • Number of GD packets, transmitter, max.

 

4

  • Number of GD packets, receiver, max.

 

4

  • Size of GD packets, max.

 

22 byte

  • Size of GD packet (of which consistent), max.

 

22 byte

S7 basic communication

 

 

  • supported

 

Yes

  • User data per job, max.

 

76 byte

  • User data per job (of which consistent), max.

 

76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

 

 

  • supported

 

Yes

  • as server

 

Yes

  • as client

 

No

  • User data per job, max.

 

180 byte

  • User data per job (of which consistent), max.

 

64 byte

S5-compatible communication

 

 

  • supported

 

No

Standard communication (FMS)

 

 

  • supported

 

No

Number of connections

 

 

  • overall

 

12

  • usable for PG communication

 

11

    • reserved for PG communication

 

1

  • usable for OP communication

 

11

    • reserved for OP communication

 

1

  • usable for S7 basic communication

 

10

    • Reserved for S7 basic communication

 

0

  • usable for routing

 

4; As slave only with active interface, with IM 151-7 CPU as DP master

1st interface

 

 

Type of interface

 

Integrated RS 485 interface

Physics

 

RS 485

Isolated

 

Yes

Power supply to interface (15 to 30 V DC), max.

 

80 mA

Functionality

 

 

  • MPI

 

Yes

  • DP master

 

No

  • DP slave

Yes

Yes; active / passive

  • Point-to-point connection

 

No

MPI

 

 

  • Number of connections

 

12; Notice: 12 connections per CPU, not per interface

  • Services

 

 

    • PG/OP communication

 

Yes

    • Routing

 

Yes; With master module

    • Global data communication

 

Yes

    • S7 basic communication

 

Yes

    • S7 communication

 

Yes

    • S7 communication, as client

 

No

    • S7 communication, as server

 

Yes

  • Transmission rate, max.

 

12 Mbit/s

DP slave

 

 

  • Number of connections

11

12; Notice: 12 connections per CPU, not per interface

  • Services

 

 

    • Routing

 

Yes; Only when interface active and in master mode

    • Direct data exchange (slave-to-slave communication)

Yes

Yes

    • DPV1

 

No

  • GSD file

http://www.siemens.de/profibus-gsd

http://www.siemens.de/profibus-gsd

  • Transmission rate, max.

12 Mbit/s

12 Mbit/s

  • Automatic baud rate search

 

Yes; only with passive interface

  • Transfer memory

 

 

    • Inputs

 

244 byte

    • Outputs

 

244 byte

  • Address area, max.

 

32

  • User data per address area, max.

 

32 byte; Up to max. size of the transfer memory

2nd interface

 

 

Type of interface

 

External interface via master module 6ES7138-4HA00-0AB0

Physics

 

RS 485

Isolated

 

Yes

Power supply to interface (15 to 30 V DC), max.

 

No

Functionality

 

 

  • MPI

 

No

  • DP master

 

Yes

  • Point-to-point connection

 

No

DP master

 

 

  • Number of connections, max.

 

12; Notice: 12 connections per CPU, not per interface

  • Services

 

 

    • PG/OP communication

 

Yes

    • Routing

 

Yes

    • Global data communication

 

No

    • S7 basic communication

 

Yes; I blocks only

    • S7 communication

 

Yes

    • S7 communication, as client

 

No

    • S7 communication, as server

 

Yes

    • Equidistance mode support

 

Yes

    • SYNC/FREEZE

 

Yes

    • Activation/deactivation of DP slaves

 

Yes

    • Direct data exchange (slave-to-slave communication)

 

Yes

    • DPV1

 

Yes

  • Transmission speeds, max.

 

12 Mbit/s

  • Number of DP slaves, max.

 

32; Per station

  • Address area

 

 

    • Inputs, max.

 

2 Kibyte

    • Outputs, max.

 

2 Kibyte

  • User data per DP slave

 

 

    • Inputs, max.

 

244 byte

    • Outputs, max.

 

244 byte

Isochronous mode

 

 

Isochronous mode

 

No

CPU/ programming

 

 

Configuration rules

 

max. 63 peripheral modules per station; station width < 1 m or < 2 m; max. 10 A per load group (power module); master interface module on right next to IM 151-7 CPU (X2 interface)

Programming language

 

 

  • STEP 7

 

Yes

  • LAD

 

Yes

  • FBD

 

Yes

  • STL

 

Yes

  • SCL

Yes

Yes; Optional

  • GRAPH

 

Yes; Optional

Command set

Binary logic operations, bracketed operations, result allocation, saving, counting, loading, transferring, comparing, shifting, rotating, complementation, calling blocks, fixed point arithmetic, floating point arithmetic, jump functions

See instruction list

Nesting levels

8

8

Know-how protection

 

 

  • User program protection/password protection

Yes

Yes

System functions (SFC)

Interrupt and error processing, copy data, clock functions, diagnostic functions, module parameterization, operating mode transitions

See instruction list

System function blocks (SFB)

 

See instruction list

Isolation

 

 

Isolation checked with

 

500 VDC

Galvanic isolation

 

 

between load voltage and all other switching components

 

Yes

between PROFIBUS DP and all other circuit components

 

Yes

Permissible potential difference

 

 

between different circuits

 

75 VDC / 60 VAC

Environmental requirements

 

 

Operating temperature

 

 

  • Min.

0 °C

 

Dimensions and weight

 

 

Dimensions

 

 

  • Width

60 mm

60 mm; DP master module: 35 mm

  • Height

119.5 mm

119.5 mm

  • Depth

75 mm

75 mm

Weight

 

 

  • Weight, approx.

200 g

200 g; DP master module: Approx. 100 g